00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第97页
Introduction SIPLACE on the World Wide Web ( WWW) Staff Qualifications and Tra ining Stationary Camera Typ e 33/36 Stationäre Kamera Typ 33/36 97 1.3.5 SIPLACE on the World Wide Web (WWW) Log into our SIPLACE ® homepage …

Introduction
Other Instructions Release History
96 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
1.3.3.3 Handling ESD Modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other work.
If it is necessary, make sure that you do not touch the pins or printed conductors when you pick up flat
modules.
Do not touch components unless
▪ You are constantly earthed by an ESD wrist strap or
▪ You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a conductive
and earthed object immediately before you touch the module (such as unpainted parts of a switch cab-
inet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g. plastic
films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD foam,
ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10 cm away
from the screen.
1.3.3.4 Measurements and Modifications to ESD Modules
Measurements of the assemblies may only be taken if
▪ The measuring device has been grounded (e.g. via protective conductor) or
▪ The measuring head of the potential-free measuring device has been briefly discharged before
measurement (e.g. touching blank metal control unit housing).
► Always use an earthed soldering iron if you carry out any soldering work.
1.3.3.5 Dispatching ESD Modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags or met-
al sleeves) and dispatch them in conductive packaging.
► If the packaging is not conductive, place the modules in a conductive envelope before packaging.
Use conductive foam rubber, ESD bags, domestic aluminum foil or paper, for example. NEVER use
plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or short-
circuit the battery terminals and, if necessary, first cover the terminals with insulating tape or mate-
rial.
1.3.4 Release History
Release Changes
07/2012 First edition
Introduction
SIPLACE on the World Wide Web (WWW) Staff Qualifications and Training
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 97
1.3.5 SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
► You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can access the
SIPLACE User Group
. Here you can call up special
information about our placement systems e.g.
▪ Technical documentation,
▪ Technical information,
▪ Spare parts lists etc.
Registration for the user group is very simple:
► Click on the Register link.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.
1.4 Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op-
eration and maintenance of placement machines and add-on devices and are suitably qualified. e.g:
▪ Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
▪ Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord-
ance with normal safety standards.
▪ Have received first aid training.

Introduction
Abbreviations SIPLACE on the World Wide Web (WWW)
98 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
1.5 Abbreviations
Abbreviations Description
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
CO Component
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
FS Function status, version
HRK Head reconfiguration kit
PCB Board
P&P Pick&Place
TH TwinHead
VCU Vision Control Unit, also: Control Unit Vision Stationary
WPC Wafflepack Changer
WPC4/5/6 Wafflepack Changer Version 4/5/6