00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第139页

Installation Mechanical Assembly Installa tion on SX1/SX2 Machines Stationary Camera Typ e 33/36 Stationäre Kamera Typ 33/36 139 3.4.3.2 Installation of Camera with Keyhole (for Camera Type 33 from Version 06) CAUTION Ob…

100%1 / 172
Installation
Installation on SX1/SX2 Machines Mechanical Assembly
138 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
3.4.3.1 Installation of Camera with Set Screws (for Camera Type 33 up to Version 05)
CAUTION
Observe the installation height
When fitting the camera, observe the correct installation height. Othwerwise there is a risk of
head crash!
Please also observe section "4.1 Installation Height of the Stationary Camera" [ 153].
Screw the two set screws (with the Allen key side on
the outside) as assembly aid to the surface, on which
the camera is to be screwed. Select either the upper
or lower holes, depending on the installation height
required (1).
Carefully push the lower section of the camera on to
the set screws.
Fix the lower section of the camera with 2 screws to
the unused screw openings.
Remove the two set screws and replace with 2 nor-
mal screws.
The lower section of the camera has now been fixed into
place.
Installation
Mechanical Assembly Installation on SX1/SX2 Machines
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 139
3.4.3.2 Installation of Camera with Keyhole (for Camera Type 33 from Version 06)
CAUTION
Observe the installation height
When fitting the camera, observe the correct installation height. Othwerwise there is a risk of
head crash!
Please also observe section "4.1 Installation Height of the Stationary Camera" [ 153].
Screw the two top fastening screws loosely into the
surface onto which the camera will be fitted later on.
The screws should be tightened enough to still allow
the camera to be easily hooked in.
Carefully hook the top holes on the lower section of
the camera (1) onto the fastening screws.
Fix the lower section of the camera with 2 screws to
the lower screw openings 2. Observe the required in-
stallation height.
Tighten the two top fastening screws.
The lower section of the camera has now been fixed into
place.
Installation
Installation on SX1/SX2 Machines Electrical Connections
140 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
3.4.4 Electrical Connections
Direct connection to the machine
Connection to FC cameras (type 25 with version 05)
If there is a version 05 FC camera present, the IC camera will be connected to this. From this version
onwards, the FC camera has a multiplexer, which provides the connections for the IC and FC cameras.
This enables you to operate a placement area with up to four stationary cameras.
1. Camera cable (hotlink cable)
2. 2 x CAN bus cable (For IC and FC camera)
3. Power supply
The opening in the machine frame contains two CAN bus
cables (1), the camera cable (2) (hotlink cable) and the
power supply cable (3).
Connect the camera cable (1), the CAN bus cable (2)
and the power supply cable (3) to the stationary cam-
era, according to the respective camera configura-
tion.