00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第108页
Installation General Preparations Moving COT Insert with X Tables 108 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/ 36 3.1.1.3 Dismantling the Lower Side Cover (SX4) ► Loosen the two screws (1 ) , in order to pu…

Installation
Moving COT Insert with X Tables General Preparations
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 107
3.1.1 Moving COT Insert with X Tables
To access the stationary camera installation position, you may need to loosen the COT insert and push
it forwards.
3.1.1.1 Overview
3.1.1.2 Dismantling the Side Cover (X Series and D3)
CAUTION
Service manual
► Read the section "Replacing the COT Insert" in your service manual!
NOTICE
Example of X series
The following description of how to move the COT insert uses the example of an X series ma-
chine, unless it states otherwise. The procedure is the same for other machines.
NOTICE
Mark the positions of the screws
► Mark the positions of all screws, to make clear assignment easier later on.
COT insert (using example of X series)
1. COT insert assembly
2. Installation position for stationary cameras
1
2
► Undock the component trolley from the placement
machine at the installation position of the stationary
camera.
► Switch the placement machine off at the main switch.
► Loosen the screw (2), fastening the side cover (1) on
the inside.

Installation
General Preparations Moving COT Insert with X Tables
108 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
3.1.1.3 Dismantling the Lower Side Cover (SX4)
► Loosen the two screws (1), in order to pull out the side
cover.
► Loosen the four screws (2) fastening the side cover
and remove these. Hold the side cover while you are
removing the screws.
Position of protective switches on the placement machine
1. Protective cover switch, location 1
2. Protective cover switch, location 2
3. Protective cover switch, location 3
4. Protective cover switch, location 4
T = PCB direction of transport
► To do this, loosen the 6 screws fastening the side
cover in the order (1) to (4) and remove these. While
unscrewing, always hold on to the side cover, to pre-
vent it falling off.

Installation
Moving COT Insert with X Tables General Preparations
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 109
3.1.1.4 Moving the COT Insert
► On both sides of the COT insert you will find a black
cap (1). Remove the cap to the inside of the machine,
if you need to access the fitting screw behind it. To do
this, simply loosen the screw fastening the cap and
take off the cap.
NOTICE!
The cap on the outer side need not be removed.
► Mark the mounting position of the COT insert.
► Loosen the five screws (1) fastening the COT insert.
► Loosen the fitting screw (2) on the inside of the ma-
chine.
CAUTION!
The cover of the power supply (2) must be closed.
If the cover of the power supply is not closed there is a
risk that the COT insert will fall out when moved..
Close the cover of the power supply.
► Pull out the COT insert carefully until it touches the
protective door of the power supply (1).
1
1
1
1
2
1