00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第116页
Installation Installation on X Series and D3 Machines Electrical Connections 116 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/ 36 Connection to the Vision Control Unit Stationary Up To Serial Number B325 and IC …

Installation
Electrical Connections Installation on X Series and D3 Machines
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 115
See also
3.2.3.3 Connecting the Hotlink Cable to the Computer Unit [ ➙ 123]
Camera (FS02)
1. X5: Vision cable 34-pin, from IC camera to Vision
Control Unit, stationary
2. X3: Cable from camera bus to computer unit
► Connect the cable (1) to the camera. This creates the
connection to the Vision Control Unit, stationary.
► Connect the cable (2) to the camera. This creates the
connection to the computer unit. Continue by reading
the following section: "3.2.3.3 Connecting the Hotlink
Cable to the Computer Unit" [ ➙ 123]
For more information, refer to the circuit diagrams:
"4.4.1.1 Camera Up To FS02" [ ➙ 159]
Vision LED driver board SST20 (up to FS02)
1. X2: Not relevant
2. X3: Cable from camera bus to computer unit
3. X4: Jumper must be connected
4. X5: Vision cable 34-pin, from IC camera
[03003439-xx] to Vision Control Unit, stationary
5. X3: Not relevant

Installation
Installation on X Series and D3 Machines Electrical Connections
116 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
Connection to the Vision Control Unit Stationary Up To Serial Number B325 and IC Camera FS01 and
FS02
NOTICE
Observe the machine serial number and camera FS number.
Observe this section for X series machines up to serial number B325 and IC cameras with FS01
or FS02.
NOTICE
CPP and VCU
The Vision Control Unit (VCU) does not support CPP heads. CPP heads and the corresponding
stationary cameras are therefore only possible from machine serial number B326.
► In this case, read the corresponding assembly instructions for information about further re-
strictions.
NOTICE
TQM module
The TQM module [03003536-xx] is not part of the camera delivery package and will need to be
ordered separately if required.
NOTICE
Control Unit 1 Vision, Stationary [00363961-xx]
The "Control Unit 1 Vision, Stationary" [00363961-xx] is part of the "Reconfig. parts kit parts kit
for X series/TwinHead" [03041487-xx].
VCU
► Connect the TQM module to the "Control Unit 1 Vi-
sion, Stationary" [00363961-xx] board.
► Fit the "Control Unit 1 Vision, Stationary" [00363961-
xx] with the connected "TQM167 SIPLACE embed-
ded module" [03003536-xx] in the relevant slot (1).
▪ The VCU for PA1 is located in the subdistributor (lo-
cation 4).
▪ The VCU for PA2 is located in the main distributor (lo-
cation 2).

Installation
Electrical Connections Installation on X Series and D3 Machines
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 117
VCU with CAN bus and TQM module
► Connect the CAN bus (3) to X2.
► Connect the voltage supply cable for the "Control Unit 1 Vision, Stationary" (6).
NOTICE
BIOS and eSW version
After starting the machine, check the BIOS and Vision system application versions and, if nec-
essary, update the system with a software download.
1 TQM module [03003536-xx] on
"Control Unit 1 Vision, Stationary"
[00363961-xx]
2 CAN bus cable (X2rd)
3 DIP switch VCU
4 PA1: Subdistributor
Cable vision control IC camera 1
[03003449-xx]
To subdistributor (X4rd)
5 PA1: Subdistributor
Cable vision control FC camera 1
[03003450-xx]
To subdistributor (X5rd)
PA2: Main distributor
Cable vision control IC camera 2
[03003439-xx]
To main distributor (X4rd)
PA2: Main distributor
Cable vision control FC camera 2
[03003440-xx]
To main distributor (X5rd)
6 Cable: Voltage supply "Control Unit 1 Vi-
sion, Stationary" (X3rd)