1 Introduction 1.5 Abbreviations 120 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021

100%1 / 208
1 Introduction
1.5 Abbreviations
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 119
1.5 Abbreviations
Abbreviations Description
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P20x Collective term for all C&P20, C&P20 A, C&P20 M, C&P20 P and C&P20 P2
CPP Collect&Pick&Place head
CPx Collective term for all CPP, CP20, CP12 and/or CP6
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
P&P Pick&Place
NC Nozzle changer
SC Station computer
TH TwinHead
1 Introduction
1.5 Abbreviations
120 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
2 Brief description
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 121
2 Brief description
Every Collect&Place head has a separate vacuum generator that supplies the holding and place-
ment circuit with the vacuum that it needs.
The vacuum generator for the placement heads works according to the Venturi principle. In com-
bination with a vacuum pump, the compressed air consumption can be significantly reduced for the
SIPLACE SpeedStar (C&P20x). The ongoing operating costs are reduced according to the energy
costs.
NOTICE
Maximum of two SIPLACE C&P20x
This vacuum pump can supply a maximum of two SIPLACE C&P20x. If using a SIPLACE
X4S / X4iS with four SIPLACE C&P20x, you therefore need two vacuum pumps. These
vacuum pumps are fitted at locations 1 and 4, behind the COT inserts in the machine base.
NOTICE
Conversion
If you need to convert a gantry from SIPLACE C&P20x to SIPLACE Twin or SIPLACE CPP,
you must re-establish the original compressed air supply for this gantry. That means, you
must perform a conversion reversal on all assemblies for this gantry.
NOTICE
Partial conversion
Partial conversion of the pneumatic unit, for example, involving disconnection of the gantry
hoses (additional vacuum hoses) during compressed air operations, can lead to serious
placement machine malfunctions.
NOTICE
Retrofitting
If you need to convert a gantry from SIPLACE Twin or SIPLACE CPP to SIPLACE C&P20x
with vacuum function, you must retrofit the vacuum equipment for this gantry.
NOTICE
Compressed air operation
If you operate a C&P20x which has been converted for vacuum operation at a gantry with
compressed air, this could lead to serious damage to the placement head if the silicon
hoses to the segments should loosen.
NOTICE
Folded hoses
Make sure that the hoses are never folded or pinched, not even during unpacking, as this
makes them unsuitable for further use.
NOTICE
SIPLACE C&P20P/P2 usually with vacuum
If the SIPLACE C&P20P/P2 is to be used on a machine in compressed air mode (Venturi),
the head must be converted with the "Conversion kit compressed air operation SIPLACE
C&P20P" [03106765-xx].
For a conversion reversal from compressed air mode back to vacuum pump mode, you
need the "Aperture ring assembly C&P20P [03116883-xx].