00198599-02_AI_Vacuumpump_X-Series-S-from-Hxxxx_DE_EN.pdf - 第153页

3 Installation 3.5 Installing the vacuum pump Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 153 3.5.5 Preparing the vacuum distributor Fig.45: Vacuum distributor …

100%1 / 208
3 Installation
3.5 Installing the vacuum pump
152 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
Detailed circuit diagram vacuum pump (new)
Fig.44: Detailed circuit diagram vacuum pump (new)
3 Installation
3.5 Installing the vacuum pump
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 153
3.5.5 Preparing the vacuum distributor
Fig.45: Vacuum distributor without pump
Pull the tube that has been disconnec-
ted from the proportional controller
back to the vacuum pump installation
location and connect it to the vacuum
distributor(4)
.
Pull the transparent vacuum hoses (two
per gantry) that belong to the gantry to
be converted out of the machine base.
The vacuum hoses in the machine
have their maximum length.
Shorten the two vacuum hoses to the
length required to connect them to the
vacuum distributor, which will be run in-
side the machine base at(1)
.
Mark the vacuum hoses with the relev-
ant gantry number.
Connect the size 12 PUN hose(2) and
the vacuum hoses(3)
to the vacuum
distributor.
Perform the above mentioned tasks for all gantries to be converted.
Fasten the vacuum hoses for the unconverted gantries with a cable tie and push these hoses
upwards in the machine base, to make room for installation of the pump.
3 Installation
3.5 Installing the vacuum pump
154 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
3.5.5.1 Fitting the vacuum valve or bypass converter
Machines with only one head at a vacuum pump require a vacuum valve or bypass converter to be
fitted for introduction of leaked air.
Bypass converter [03222472‑xx]
Vacuum valve Becker ST 613-0-2 [03109300‑xx]
Installing the vacuum valve
Fig.46: Fitting the vacuum valve
Unscrew a Festo screw joint(1).
Fit the "reducing socket IG = 1 Rp AG = 1/2 R"(2) [03123422‑xx].
Fit the "vacuum valve Becker ST 613-0-2"(3) [03109300‑xx]
Fitting the bypass converter
Fig.47: Fitting the bypass converter
Unscrew a Festo screw joint(1).
Fit the "push-in L-fitting QS-1/2-10"(2) [03038816‑xx].
Fit the bypass converter(3) [03222472‑xx].
Setting
Set the vacuum valve/bypass converter as follows:
Equip the SIPLACE C&P20x with 4004/6004 nozzles.
The vacuum difference from open to closed should be 95mbar, the closed value should be
at least -750mbar.
The other head should be without nozzles.