100%1 / 208
3 Installation
3.5 Installing the vacuum pump
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 163
3.5.11 Installing the fan plate
Fig.68: Connecting the fan cable (example of old vacuum
pump shown)
Plug the fan cable W3 into connector
X1 FANVP1 and the fan cable W4 into
connector X1 FanVP2 at the fan.
Secure the cable using a cable tie.
Fig.69: Holes drilled for screws to fasten the fan plate
(example of old vacuum pump shown)
Fig.70: Fan plate
The cooling plate(1) is fitted after all other
work has been completed.
Fasten the fan plate(1) [03098622‑xx]
from the outside with four screws
[03007765‑xx] (M6x16) and wash-
ers(2)
[03022691‑xx] (M6).
3 Installation
3.5 Installing the vacuum pump
164 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
Fig.71: Cooling plate, fitted
Fig.72: Pneumatic distributor and fan
Fan function test
Perform a fan function test as follows:
Switch the placement machine on at the main switch. The vacuum pump must also switch it-
self on, although this might not occur immediately after the machine is switched on.
Check the direction of fan operation. The fan must blow air into the machine.
If the fan is running incorrectly, turn the 24Volt in the Mini Mad BN Lock connection.
3 Installation
3.6 Final work
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 165
3.6 Final work
3.6.1 Docking the component trolley
Fit the empty tape duct and fix into place with four screws, inserted from below and attached
to the assembly brackets on the left and right.
Dock the component trolleys into place.
3.6.2 Switch on machine
CAUTION
Switch-on preconditions
Before switching on, perform the following checks to prevent injuries or serious damage to
property:
Make sure of the following before you switch the compressed air supply back on:
Check that all hose connections are correctly assigned (also that there is no com-
pressed air in the vacuum hose).
Check that all conditions for switch-on of the vacuum pump and connected placement
machine have been fulfilled, as specified in the user manuals.
Open the compressed air shut-off valve.
Close all doors.
Switch the machine on at the main switch.