3 Installation
3.5 Installing the vacuum pump
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 163
3.5.11 Installing the fan plate
Fig.68: Connecting the fan cable (example of old vacuum
pump shown)
► Plug the fan cable W3 into connector
X1 FANVP1 and the fan cable W4 into
connector X1 FanVP2 at the fan.
► Secure the cable using a cable tie.
Fig.69: Holes drilled for screws to fasten the fan plate
(example of old vacuum pump shown)
Fig.70: Fan plate
The cooling plate(1) is fitted after all other
work has been completed.
► Fasten the fan plate(1) [03098622‑xx]
from the outside with four screws
[03007765‑xx] (M6x16) and wash-
ers(2)
[03022691‑xx] (M6).

3 Installation
3.5 Installing the vacuum pump
164 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
Fig.71: Cooling plate, fitted
Fig.72: Pneumatic distributor and fan
Fan function test
Perform a fan function test as follows:
► Switch the placement machine on at the main switch. The vacuum pump must also switch it-
self on, although this might not occur immediately after the machine is switched on.
► Check the direction of fan operation. The fan must blow air into the machine.
If the fan is running incorrectly, turn the 24Volt in the Mini Mad BN Lock connection.

3 Installation
3.6 Final work
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 165
3.6 Final work
3.6.1 Docking the component trolley
► Fit the empty tape duct and fix into place with four screws, inserted from below and attached
to the assembly brackets on the left and right.
► Dock the component trolleys into place.
3.6.2 Switch on machine
CAUTION
Switch-on preconditions
Before switching on, perform the following checks to prevent injuries or serious damage to
property:
Make sure of the following before you switch the compressed air supply back on:
► Check that all hose connections are correctly assigned (also that there is no com-
pressed air in the vacuum hose).
► Check that all conditions for switch-on of the vacuum pump and connected placement
machine have been fulfilled, as specified in the user manuals.
► Open the compressed air shut-off valve.
► Close all doors.
► Switch the machine on at the main switch.