5 Converting to compressed air supply  Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 169 5 Converting to compressed air supply Perform the following steps for a c…

100%1 / 208
4 Replacement
4.2 Replacement of old vacuum pump with new one
168 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
4.2.2 Removal/installation
Also observe the relevant chapter in section 3 "Installation" [}131].
Remove the old vacuum pump, including all metal parts attached to it.
Dismantle the old "vacuum pump control SMPS X-SeriesS" [03121065‑xx].
Fig.76: Vacuum pump control SMPS
 CAUTION!
Do not replace!
The vacuum pump controls for the old
and new vacuum pump look very sim-
ilar.
Make sure that you use the version de-
signed for the vacuum pump you are
using.
When replacing an old vacuum pump
with a new one, make sure that you al-
ways replace the vacuum pump con-
trol as well!
.
Vacuum pump Correct version of the QM1 assembly
Old Becker VX 4.25 vacuum pump
with cable [03128463‑xx]
Vacuum pump control SMPS X-Series S [03121065‑xx]
New Becker VX 4.25 IE3 vacuum
pump with cable [03212135‑xx]
Vacuum pump control SMPS [03218396‑xx]
Fit the new "vacuum pump control SMPS" [03218396‑xx].
Fit the "conversion kit for 110V vacuum pump IE3" [03224408-xx].
Fit the new vacuum pump.
5 Converting to compressed air supply
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 169
5 Converting to compressed air supply
Perform the following steps for a conversion from vacuum operation to compressed air operation.
For details, read the relevant installation chapters in this manual.
Converting the SIPLACE C&P20x
Dismantling the used tape chute
Removing the connector unit box
Replacing the cooling plate
Removing the exhaust air disposal
Removing the cap if required
Removing the exhaust duct
Removing the vacuum pump
Removing the supply cables
Rewiring the I/O distributor
Converting the hoses, installing the proportional controller, if required
Converting the gantries
Installing the used tape chute
5 Converting to compressed air supply
170 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021