00198599-02_AI_Vacuumpump_X-Series-S-from-Hxxxx_DE_EN.pdf - 第169页
5 Converting to compressed air supply Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 169 5 Converting to compressed air supply Perform the following steps for a c…

4 Replacement
4.2 Replacement of old vacuum pump with new one
168 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
4.2.2 Removal/installation
Also observe the relevant chapter in section 3 "Installation" [}131].
► Remove the old vacuum pump, including all metal parts attached to it.
► Dismantle the old "vacuum pump control SMPS X-SeriesS" [03121065‑xx].
Fig.76: Vacuum pump control SMPS
CAUTION!
Do not replace!
The vacuum pump controls for the old
and new vacuum pump look very sim-
ilar.
Make sure that you use the version de-
signed for the vacuum pump you are
using.
When replacing an old vacuum pump
with a new one, make sure that you al-
ways replace the vacuum pump con-
trol as well!
.
Vacuum pump Correct version of the QM1 assembly
Old Becker VX 4.25 vacuum pump
with cable [03128463‑xx]
Vacuum pump control SMPS X-Series S [03121065‑xx]
New Becker VX 4.25 IE3 vacuum
pump with cable [03212135‑xx]
Vacuum pump control SMPS [03218396‑xx]
► Fit the new "vacuum pump control SMPS" [03218396‑xx].
► Fit the "conversion kit for 110V vacuum pump IE3" [03224408-xx].
► Fit the new vacuum pump.

5 Converting to compressed air supply
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 169
5 Converting to compressed air supply
Perform the following steps for a conversion from vacuum operation to compressed air operation.
For details, read the relevant installation chapters in this manual.
●
Converting the SIPLACE C&P20x
●
Dismantling the used tape chute
●
Removing the connector unit box
●
Replacing the cooling plate
●
Removing the exhaust air disposal
●
Removing the cap if required
●
Removing the exhaust duct
●
Removing the vacuum pump
●
Removing the supply cables
●
Rewiring the I/O distributor
●
Converting the hoses, installing the proportional controller, if required
●
Converting the gantries
●
Installing the used tape chute

5 Converting to compressed air supply
170 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021