7.3 Error message: 30356 Vacuum in holding circuit too low
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 183
7.3 Error message: 30356 Vacuum in holding circuit too low
Error / problem
Error message 30356 Vacuum in holding circuit too low
On machines of the SIPLACE X-Series S with vacuum pump, the additional vacuum tube on the
gantry can rupture.
Cause of Hazard
If the gantry with the placement head moves to the inner position very often, the tube is slightly fol-
ded at the interface to the gantry. In the long run, this can cause a rupture of the vacuum tube.
Fig.87: Rupture on a vacuum tube (old duo tube [03075472‑xx])