7 Appendix 7.4 Excerpts from the service manual 200 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 7.4.6.2 Replacing the silencer (Venturi mode only) Parts 03043707…

7 Appendix
7.4 Excerpts from the service manual
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 199
Fig.116: Greasing the O-ring
► Grease the O-ring. To do this, use a
cleaning stick coated with "Isoflex To-
pas 5051 50ml (green)".
Fig.117: Fitting the cover
► Venturi operation only:
Fit the silencer. Tighten the screw
fastening the silencer only hand-tight
.
► Vacuum pump operation only:
Fit the cover. Tighten the screw fasten-
ing the cover only hand-tight
.
► Follow the removal instructions in reverse order for further installation.

7 Appendix
7.4 Excerpts from the service manual
200 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
7.4.6.2 Replacing the silencer (Venturi mode only)
Parts
03043707-xx Silencer
Overview
Fig.118: Silencer (example of SIPLACE C&P20A shown)
1. Silencer on holding circuit
2. Fastening screw
Preparation
► Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
CAUTION
Camera
► Make sure that you do not damage or contaminate the camera lens system.
► Make sure that the component sensor protective cap is fitted.
Removal
► Remove the screw fastening the silencer.
► Carefully lever out the silencer.
Installation
► Follow the removal instructions in reverse order for further installation. Also observe the fol-
lowing instructions:
CAUTION
Installation instructions
► Carefully press the new silencer down, onto the holding circuit.
► Carefully hand-tighten the screw fastening the silencer.

7 Appendix
7.4 Excerpts from the service manual
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 201
7.4.7 SIPLACE C&P20 P2
7.4.7.1 Replacing the aperture ring/holding circuit/sealing disc
Parts – vacuum operation
Fig.119: Aperture ring
1 03165750-xx Aperture ring assembly SIPLACE C&P20 P2 (including sealing disc and
cover)
2 03006234-xx O-Ring 40x1.5
3 03105638-xx Sealing disc C&P20P
4 --- Pins
5 --- Groove: this groove shows the position of the pin (4) for easier installation.
6 03165754-xx Cover assembly C&P20 P2
03110132‑xx Sealing gasket M4 (for cover)