3 Installation 3.5 Installing the vacuum pump Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 143 3.5 Installing the vacuum pump CAUTION Safety instructions and manu…

3 Installation
3.4 Converting the SIPLACE C&P20x
142 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
3.4.4 Installing the pressure sensor
NOTICE
Pressure sensor
Each SIPLACE C&P20P/P2 requires a pressure sensor in vacuum operation.
► Check whether a pressure sensor is present on each SIPLACE C&P20P/P2.
► One upgrade kit pressure sensor for vacuum C&P20P [03108457‑xx] may be re-
quired for each placement head to be retrofitted.
Fig.23: Pressure sensor
Pressure sensor vacuum connection C&P20
P [03108303-xx]
Fig.24: Pressure sensor on the gantry
1. Pressure sensor
2. Base adapter
The pressure sensor is located on the
vacuum distributor of the gantry and is con-
nected to the base (X8) adapter.
See also 7.4.2 "Replacing the pressure sensor [03108303-xx]" [}190].

3 Installation
3.5 Installing the vacuum pump
Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021 143
3.5 Installing the vacuum pump
CAUTION
Safety instructions and manufacturer's instructions
In addition to the safety instructions in the introductory chapter, the manufacturer's safety
instructions, installation and setup instructions apply to the vacuum pump and must be ob-
served.
Avoid switching the placement machine and vacuum pump on and off multiple times within
a short period. This can have a negative influence on the service life of the pump.
The placement machine monitors when the vacuum pump is switched on and off e.g. after
longer production standstill times.
3.5.1 Preparing the vacuum pump
Select the relevant chapter for your version of the vacuum pump:
●
3.5.1.1 "Preparing the vacuum pump (old)" [}143]
●
3.5.1.2 "Preparing the vacuum pump (new)" [}146]
3.5.1.1 Preparing the vacuum pump (old)
Fig.25: Filter, distributor and double nipple
1. Filters
2. Distributor
3. Double nipple
NOTICE
Distributor
First push the vacuum pump into the machine and then screw the distributor to the vacuum
pump.

3 Installation
3.5 Installing the vacuum pump
144 Assembly Instructions / Montageanleitung SIPLACE X-Series S (from/ab Hxxxx) Option Vacuum Pump 02/2021
Fig.26: Support sheet for the vacuum pump
► Push the vacuum pump into the sup-
port sheet(2)
.
► Screw the vacuum pump to the support
sheet with the four screws(1)
.
Fig.27: Fixed vacuum pump
Vacuum pump fixed to the support sheet
with screws.
Fig.28: Double nipple with Teflon tape
► Seal the double nipple (1) with Teflon
tape Loctite 55(2)
.