00197471-03_Service Manual Internal WPC5_6, EN_01-2019.pdf - 第110页

Service Manual In ternal WPC5 / WPC6  Page 3-110 See a lso … . @3.5.2 Replacing the L oad Axis Drive Motor [ ➙ 3- 35 ] ➢ Loosen the counternut fastening the sensor on the und erside of the base plate and uns crew the se…

100%1 / 172
Service Manual Internal WPC5 / WPC6
Page 3-109
3.7.17 Sensor 14 NSM module (WPC6) Tray detection sensor
Spare Parts
Sensor Tray detection load axis [03056989-xx]
Removal / Installation
Remove the cover on the load unit (see "3.5.1.1 Remove the Cover on the Load Unit" [ 3-
33]).
Dismantle the lifting magnets (see "3.5.4 Replace the Lifting Magnets" [ 3-40]).
Legend
1. Sensor tray correctly inserted
2. Sensor tray detection load axis
Disconnect connector X5 from the
circuit board.
Service Manual Internal WPC5 / WPC6
Page 3-110
See also.
@3.5.2 Replacing the Load Axis Drive Motor [
3-35]
Loosen the counternut fastening
the sensor on the underside of the
base plate and unscrew the sensor
(1).
Screw the new sensor into the table
plate.
The sensor should protrude
between 0.2 mm and 0.5 mm
above the table plate. Check this
with a straight edge (2).
Use a counternut to fix the sensor
on the underside (1).
Reconnect connector X5 to the
circuit board.
Service Manual Internal WPC5 / WPC6
Page 3-111
3.7.18 Sensor 16 NSM module (WPC6) Safety Sensor for the Hand Guard
Spare Part
Safety sensor hand guard [03056990-xx]
Preparations
Loosening the belt tension
Loosen the tension of the load axis
drive belt (2) at the tensioning
screw behind the tower (1).
Removing the base plate
Loosen the screws fixing the motor
to the base plate at (3).
Lift off the base plate and turn it
over.