00197471-03_Service Manual Internal WPC5_6, EN_01-2019.pdf - 第110页
Service Manual In ternal WPC5 / WPC6 Page 3-110 See a lso … . @3.5.2 Replacing the L oad Axis Drive Motor [ ➙ 3- 35 ] ➢ Loosen the counternut fastening the sensor on the und erside of the base plate and uns crew the se…

Service Manual Internal WPC5 / WPC6
Page 3-109
3.7.17 Sensor 14 NSM module (WPC6) – Tray detection sensor
Spare Parts
• Sensor Tray detection load axis [03056989-xx]
Removal / Installation
➢ Remove the cover on the load unit (see "3.5.1.1 Remove the Cover on the Load Unit" [➙ 3-
33]).
➢ Dismantle the lifting magnets (see "3.5.4 Replace the Lifting Magnets" [➙ 3-40]).
Legend
1. Sensor tray correctly inserted
2. Sensor tray detection load axis
➢ Disconnect connector X5 from the
circuit board.

Service Manual Internal WPC5 / WPC6
Page 3-110
See also….
@3.5.2 Replacing the Load Axis Drive Motor [
➙
3-35]
➢ Loosen the counternut fastening
the sensor on the underside of the
base plate and unscrew the sensor
(1).
➢
Screw the new sensor into the table
plate.
➢ The sensor should protrude
between 0.2 mm and 0.5 mm
above the table plate. Check this
with a straight edge (2).
➢ Use a counternut to fix the sensor
on the underside (1).
➢ Reconnect connector X5 to the
circuit board.

Service Manual Internal WPC5 / WPC6
Page 3-111
3.7.18 Sensor 16 NSM module (WPC6) – Safety Sensor for the Hand Guard
Spare Part
• Safety sensor hand guard [03056990-xx]
Preparations
Loosening the belt tension
➢ Loosen the tension of the load axis
drive belt (2) at the tensioning
screw behind the tower (1).
Removing the base plate
➢ Loosen the screws fixing the motor
to the base plate at (3).
➢ Lift off the base plate and turn it
over.