3.7.9 Sensor 5 Top Lifting axis limited switch
Spare Part
• Top lifting axis limit switch [03047279-01]
Removal / Installation
➢ Mark the exact position of the limit switch.
➢ Loosen the two fastening screws (1) on the limit switch.
➢ Remove the fixture plate (3).
➢ Loosen the cable clamps and remove the cable ties.
➢ Unthread the connection cable as far as the control unit back plane and unplug it from the
terminal strip.
➢ Fit the new limit switch.
➢ Fit the new limit switch with fixture plate (3) at the marked installation position.
➢ Restore the electrical connection and fix the connection cable into place.

Service Manual Internal WPC5 / WPC6
Page 3-96
Settings
➢ Check the function and correct position of the limit switch. The limit switch must switch when
the lifting axis moves over the switch (end position).
➢ To do this, open the following function in the main view:
⇨ Sensors and Functions ⇨ Location ⇨ Check functions for WPC ⇨ Advanced functions
.
➢ Select the
Lifting axis
radio button in the Axis entry field.
➢ Select the
Limit switch
- button in the input area. (see also "4.1.4 Calibrating the Limit Switch"
[➙ 4-122]).
⇨ The lifting axis will be moved so that an actuator on the lifting axis moves over the limit
switch. The limit (end position) will be calculated.
⇨ Go to the main view and open the menu function
⇨ Sensors and Functions ⇨ Location ⇨ Check functions for WPC ⇨ Advanced functions ⇨ WPC E/A
Ports
. Make sure that the
Lifting axis top limit switch
view option is enabled.
⇨ A dialog box will open and the calculated value will be shown. The permissible limits
(minimum/maximum position) will also be shown. The end position must be within these
limits.
➢ Check the permissible limits against the value actually measured.
➢ If necessary, correct the mechanical position of the limit switch and repeat the measurement
procedure.
➢ If the value is within the permissible limits, save the data by clicking on
Accept .
➢
Seal the two mounting bracket fastening screws with locking varnish.

Service Manual Internal WPC5 / WPC6
Page 3-97
3.7.10 Sensor 5 Bottom lifting axis limit switch
Spare Part
• Bottom lifting axis limit switch [03047280-01]
Removal / Installation
➢ Move the lifting axis upwards into the refill position. The limit switch is located in the frame,
under the lifting axis.
➢ Remove the front cover (on the lifting axis drive motor). You can now access the opening for
the limit switch connection cable.
➢ Mark the exact position of the limit switch.
➢ Loosen the two fastening screws (1) on the limit switch.
➢ Remove the fixture plate (4).
➢ Loosen the cable clamps and remove the cable ties.
➢ Unthread the connection cable as far as the control unit back plane and unplug it from the
terminal strip.
➢ Fit the new limit switch with fixture plate (4) at the marked installation position.
➢ Align the limit switch parallel to the stopper edge (2).
➢ Restore the electrical connection and fix the connection cable into place.