00197471-03_Service Manual Internal WPC5_6, EN_01-2019.pdf - 第129页

Service Manual In ternal WPC5 / WPC6  Page 4-129 4.2.3 Reference Proximity Switch (Bero) ➢ Select the feed axis ( 1). ➢ Select the function Reference bero (2). ➢ Select Next (3). ➢ Follow the instruction sho wn and cont…

100%1 / 172
Service Manual Internal WPC5 / WPC6
Page 4-128
Confirm the new zero point position with
Finish
(1).
Service Manual Internal WPC5 / WPC6
Page 4-129
4.2.3 Reference Proximity Switch (Bero)
Select the feed axis (1).
Select the function
Reference bero
(2).
Select
Next
(3).
Follow the instruction shown and continue with
Commit
(1).
Service Manual Internal WPC5 / WPC6
Page 4-130
Confirm the new reference point proximity switch with
Finish
(1).
Setting the Driver Cam
Loosen the screw (1), fastening the cam to the driver.
Correct the position of the cam by moving it accordingly in either the or + direction.
Retighten the screw (1) and repeat the measuring steps (see "3.7.5 Replace the Reference
Sensor, Feed Axis [03057837-xx]" [ 3-80]).
Repeat the individual steps until no more error messages appear.