00197471-03_Service Manual Internal WPC5_6, EN_01-2019.pdf - 第133页
Service Manual In ternal WPC5 / WPC6 Page 4-133 4.2.5 Teaching the WPTC Transfer Position ➢ Select the feed axis ( 1). ➢ Select the function Te ach W PTC alignment position (2). ➢ Select Next (3). ➢ Insert the calibrat…

Service Manual Internal WPC5 / WPC6
Page 4-132
➢ Confirm the new position at which the limit switch triggers with
Finish
(1).
Calibrating the limit switch +
➢ Select the feed axis (1).
➢ Select the function
Calibrate limit switch +
and continue with the same procedure as that
used for calibrating the limit switch.

Service Manual Internal WPC5 / WPC6
Page 4-133
4.2.5 Teaching the WPTC Transfer Position
➢ Select the feed axis (1).
➢ Select the function
Teach WPTC alignment position
(2).
➢ Select
Next
(3).
➢ Insert the calibration pin “Adjusting gauge small WPC” [03052363-02] on the front end of the
feed axis (1).
“
Adjusting gauge small WPC
”
[03052363-02]

Service Manual Internal WPC5 / WPC6
Page 4-134
➢ Insert the calibration pin (see figure above) and continue with
Commit
(1).
➢ Remove the calibration pin and confirm the new transfer position with
Finish
(1).