Service Manual Internal WPC5 / WPC6
Page 4-132
Confirm the new position at which the limit switch triggers with
Finish
(1).
Calibrating the limit switch +
Select the feed axis (1).
Select the function
Calibrate limit switch +
and continue with the same procedure as that
used for calibrating the limit switch.
Service Manual Internal WPC5 / WPC6
Page 4-133
4.2.5 Teaching the WPTC Transfer Position
Select the feed axis (1).
Select the function
Teach WPTC alignment position
(2).
Select
Next
(3).
Insert the calibration pin Adjusting gauge small WPC [03052363-02] on the front end of the
feed axis (1).
Adjusting gauge small WPC
[03052363-02]
Service Manual Internal WPC5 / WPC6
Page 4-134
Insert the calibration pin (see figure above) and continue with
Commit
(1).
Remove the calibration pin and confirm the new transfer position with
Finish
(1).