00197471-03_Service Manual Internal WPC5_6, EN_01-2019.pdf - 第84页
Service Manual In ternal WPC5 / WPC6 Page 3- 84 To enable the query of the t hird light barrier, for use on a "Very High Force T WIN- Head (VHF- 40mm/70N), a coding p lug is required, which is plugged into the bac…

Service Manual Internal WPC5 / WPC6
Page 3-83
Spares
Overview
For the individual WPC types, different CO-Heights to be adjusted.
WPC4: a distinction is the setting for Standard- and High- Components.
Standard: 15mm; High: 23mm.
WPC5/6 < Serial-No. 3xxx:
a distinction is the setting for Standard- and High- Components.
Standard: 15mm; High: 29mm.
Option: On WPC5 from Serial No. B1485 it is possible, in context with a „Very High Force
Pick&Place Modul (VHF-30mm/70N), to set 35mm for high components.
WPC5/6 > Serial-No. 3xxx:
a distinction is the setting for Standard-, High- and Very high- components.
Standard: 15mm; High: 32mm; Very high: 35mm (45mm Optional)
Option: In context with a „Very High Force TWIN-Head (VHF-40mm/70N), the Position Very
high components is set to 45mm.
WARNING
! DANGER of CRASH !
The Setting of 45mm requires a higher position of the gantry!.
Therefore, the 45mm can only be used with the „Twin VHF Package, 40mm, 70N with
Gantry“ (Sales number 00519986-xx)!
No.:
LS Type 1:
LS type 2:
Cable for Crash-LB CO Height
Control units
Fibre optic cable
2a/
2b
„Crash light barrier normal
components“
[03057282-xx]
„Crash-LS feed-axis normal
components”
[03108652-xx]
„Fibre opt.sensor WLL180T-M
preconfig SXa“
[03093294-xx]
„Fibre optic cable LL3-TV05
2m“
[03092407-xx]
3a/
3b
„Crash light barrier high
components“
[03057283-xx]
„Crash-LS feed-axis middle
compononents“
[03108654-xx]
„Fibre opt.sensor WLL180T-F
preconfig SXa“
[03093295-xx]
„Fibre optic cable LL3-TV05
2m“
[03092407-xx]
19a/
19b
„Crash-LS load-axis high
components“
[03108656-xx]
„Fibre opt.sensor WLL180T-F
preconfig SXa“
[03093295-xx]
„Fibre optic cable LL3-TV05
2m“
[03092407-xx]
10a/
10b
„Crash-LS normal components
BA“
[03057012--xx]
11a/
11b
„Crash-LS high components BA”
[03057291--xx]
„Crash-LS load-axis middel
components“
[03108658-xx]
„Fibre opt.sensor WLL180T-M
preconfig SXa“
[03093294-xx]
„Fibre optic cable LL3-TV05
2m“
[03092407-xx]
20a/
20b
„Crash-LS Beladeachse hohe
Bauteile WPC6“
[03108659-xx]
„Lichtleiter-Sensor WLL180T-F
vorprog SXa“
[03093295-xx]
„Fibre optic cable LL3-TV05
2m“
[03092407-xx]]
Table 1: Spares Overview Ligth barrier for component height.

Service Manual Internal WPC5 / WPC6
Page 3-84
To enable the query of the third light barrier, for use on a "Very High Force TWIN-Head (VHF-
40mm/70N), a coding plug is required, which is plugged into the backplane in the control slot
on X28.
HINWEIS / NOTICE
Monitoring of the 3
rd
CO-height (very high CO’s) only with 45mm Option
The light barrier for the 3
rd
CO-height is only monitored if the coding plug, described
below, was inserted.
To avoid collisions with the sensor retainer, the 3
rd
CO level on the feed axis is set to
35mm.
At the loading axis (NSM module) this photocell is directly set to 45mm.

Service Manual Internal WPC5 / WPC6
Page 3-85
At WPC4 and at WPC5 / WPC6 up to serial no. 3xxx-, light barriers with normal electrical conection are in
use, which were directly connected to the WPC control unit (called LB type 1 in the following).
At WPC5 / WPC6 from serial no. 3xxx-, new light barierer are in use, which are using a fibre optic cable.
Those are connected to a control unit, which is finaly connected to the WPC control unit (called LB type 2 in
the following).
Overview
LB Type 1
1. Fixing screw for Crash light barrier.
2. Fixing angle Crash light barrier (transmitter)
3. Cable fixing Crash light barrier.
4. Crash light barrier normal height Components, with
LED
5. Crash light barrier high components, with
LED.
Overview LB Type 2
1. Fibre optic cables on holders (here Receiver).
2. Fibre optic cables on holders (here
Transmitter).
3. Cable for Crash light barrier CO heights.
4. Control units:
„Fibre opt.sensor WLL180T-M preconfig SXa“
[03093294-01]
„Fibre opt.sensor WLL180T-F preconfig SXa“
[03093295-01]
Data sheet see attachment of this document!
NOTICE
Spare Parts
At LB Type 1, transmitter and receiver are one spare part.
The transmitter and the receiver of one light barrier (different cable length depending on
height type) are delivered as one spare with one part number.
Depending on the error occurring, you may need to replace the transmitter and receiver
together.