Gantry Retrofit Portalnachrüstung 123
Remove the six screws (1) from the bolt for the Y gan-
try interface.
Push the two white sleeves (1) onto the bolts as
shown in the diagram.
Fasten the cables leading from the gantry loosely, as
shown, using cable ties (1). Do not tighten the cable
ties yet.
Installation
Fitting the Y Trailing Cable for the New Gantry 2/4 3.1.4 Removing the Top Cover
124 Gantry Retrofit Portalnachrüstung
Fasten the Y motor cable (connector X4*b)
[03095097-xx] with cable ties (1) to the white sleeves.
Connect the cables (1) to the underside of the Y gan-
try interface.
Position the Y gantry interface on the six bolts.
Installation
3.1.4 Removing the Top Cover Fitting the Y Trailing Cable for the New Gantry 2/4
Gantry Retrofit Portalnachrüstung 125
Fasten the Y gantry interface with four screws 3x6
and two bolts (1). Secure the bolts with Loctite 241.
Fit a cable duct to each of the bolts.
Order: washer + cable duct + washer + screw
Secure the screws with Loctite 241.
Connect all flat ribbon cables to the top side of the Y
gantry interface.
Connect all remaining cables to the Y gantry interface
and fasten these with cable ties, as shown.
Tighten all cable ties.