00197783-01_AI_Gantry-Retrofit_X-Series_S_INTERNAL_de_en.pdf - 第124页
Installation Fitting the Y Trailing Cable for the N ew Gantry 2/4 3.1.4 Removi ng the Top Cover 124 Gantry Retrofit Portalna chrüstung ► Fasten the Y motor cable (connector X4*b) [03095097 - xx] with cable ties (1) to th…

Installation
3.1.4 Removing the Top Cover Fitting the Y Trailing Cable for the New Gantry 2/4
Gantry Retrofit Portalnachrüstung 123
► Remove the six screws (1) from the bolt for the Y gan-
try interface.
► Push the two white sleeves (1) onto the bolts as
shown in the diagram.
► Fasten the cables leading from the gantry loosely, as
shown, using cable ties (1). Do not tighten the cable
ties yet.

Installation
Fitting the Y Trailing Cable for the New Gantry 2/4 3.1.4 Removing the Top Cover
124 Gantry Retrofit Portalnachrüstung
► Fasten the Y motor cable (connector X4*b)
[03095097-xx] with cable ties (1) to the white sleeves.
► Connect the cables (1) to the underside of the Y gan-
try interface.
► Position the Y gantry interface on the six bolts.

Installation
3.1.4 Removing the Top Cover Fitting the Y Trailing Cable for the New Gantry 2/4
Gantry Retrofit Portalnachrüstung 125
► Fasten the Y gantry interface with four screws 3x6
and two bolts (1). Secure the bolts with Loctite 241.
► Fit a cable duct to each of the bolts.
Order: washer + cable duct + washer + screw
Secure the screws with Loctite 241.
► Connect all flat ribbon cables to the top side of the Y
gantry interface.
► Connect all remaining cables to the Y gantry interface
and fasten these with cable ties, as shown.
► Tighten all cable ties.