Appendix 4.1.1 Replacing the Trailing Cable Excerpts from the Service Manual Gantry Retrofit Portalnachrüstung 139 Installation ► Installation is performed by fo llowing the above instructions i n the r everse ord er. Al…

100%1 / 160
Appendix
Excerpts from the Service Manual 4.1.1 Replacing the Trailing Cable
138 Gantry Retrofit Portalnachrüstung
Carefully remove the trailing cable from the machine. You might need to enlist the help of a second
person.
Mark the positions of the hoses on both sides of the
couplings (1), so that these can be easily assigned
later on.
Disconnect the hoses from the couplings.
Mark the positions of the connectors (2) on the gantry
interface (3), so that these can be easily assigned lat-
er on.
Unplug the connectors from the gantry interface.
Loosen the screws fastening the upper end of the
trailing cable.
Dismantle the cover (1) on the trailing cable
interface (2).
Mark the cables coming from the trailing cable on the
trailing cable interface, to make clear assignment
easier later on.
Unplug the cables coming from the trailing cable at
the trailing cable interface.
Appendix
4.1.1 Replacing the Trailing Cable Excerpts from the Service Manual
Gantry Retrofit Portalnachrüstung 139
Installation
Installation is performed by following the above instructions in the reverse order. Also observe the
following instructions:
CAUTION
Always handle the trailing cable with care
If a vacuum pump is fitted, also observe the relevant assembly instructions [00196845-xx].
Always handle the new trailing cable with care.
You might need to enlist the help of a second person.
Make sure that the flat ribbon cable and the pneumatic hoses are not rubbed against any
parts or folded. Look out for sharp edges.
Prepare the trailing cable. Place the old and new trailing cables next to one another and
match the length of the new trailing cable hose to the old one.
For production reasons, the new trailing cable is supplied with a holder. This new holder
can be dismantled before installation and the holder already in the machine can be used
again.
If you use the new holder, you will need to dismantle all attached items (boards etc.) from
the old holder and attach them to the new holder.
If hose ends were damaged during removal, cut these with hose cutters.
Clean the trailing cable contact surface on the machine base with a dry cloth.
Carefully insert the new trailing cable into the prescribed position. Make sure you do not fold
or twist the trailing cable.
Check that the power track chain runs parallel to the machine base. Move the gantry back
and forth.
If it is difficult to push the hoses onto the tubes, moisten these first with white spirits or iso-
propanol.
Secure with screws with Loctite 241.
Appendix
Excerpts from the Service Manual 4.1.2 Overview of GCUs
140 Gantry Retrofit Portalnachrüstung
4.1.2
4.1.2 Overview of GCUs
Overview of GCUs
Overview GCUs