Appendix
4.2.3 Head Interface C700X-L/R HR Description of Boards
Gantry Retrofit Portalnachrüstung 157
LEDs (Hx) [03091013-01] [03091023-01]
7-segment display V2 [03091013-01] [03091023-01]
7-segment display V12 [03091013-01] [03091023-01]
DIP switch S1 [03091013-01] [03091023-01]
LED Color Status Signal name Description
H1 RD - HCU1_LED_ERROR Not used
H2 RD ON POWERFAIL_BASE PowerFail from power supply
H3 RD ON EMERGENCY-STOP_3V Emergency stop: cover opened
H4 RD ON POWERFAIL_LOCAL_3V PowerFail local: errors at 1.5V,
3.3V, 5V, +15V, -15V
H7 RD ON X_TEMP_SENS X motor: temperature too high
H8 RD - HCU2_LED_ERROR Not used
H9 RD - HCU1_LED_READY Not used
H10 RD - HCU2_LED_READY Not used
H11 GN ON LED_5V_OK FPGA OK
Display Status Description
Decimal point Flashes HCU2 OK
Display Status Description
Decimal point Flashes HCU1 OK
Switch Status Signal name Description
Gantry 1 Gantry 2 Gantry 3 Gantry 4
S1.1 OFF/ON Gantry_ID0 OFF OFF ON ON
S1.2 OFF/ON Gantry_ID1 OFF ON OFF ON
S1.3 OFF COM_BOOT_HCU ON: set HCU to bootstrap mode
S1.4 OFF RESET_HCU2 ON: Reset HCU2
S1.5 OFF RESET_HCU1 ON: Reset HCU1
S1.6 OFF FAN Not used
S1.7 OFF DCDC_OFF ON: Reset, when not all the voltages are present
S1.8 OFF HCU_1_2 Not used
Appendix
Description of Boards 4.2.4 Vision hotlink adapter [03050555-xx]
158 Gantry Retrofit Portalnachrüstung
4.2.4
4.2.4 Vision hotlink adapter [03050555-xx]
Vision hotlink adapter [03050555-xx]
03050555-01
LED [03050555-01]
LED Color Status Description
D1 GN ON +12VDC
D8 RD ON CLKUSR error
D9 GN ON +5 VDC
D10 GN OFF CRC_ERR