00197783-01_AI_Gantry-Retrofit_X-Series_S_INTERNAL_de_en.pdf - 第155页
Appendix 4.2.3 Head Interface C700X-L/R HR Description of Boa rds Gantry Retrofit Portalnachrüstung 155 4.2.3 4 . 2 . 3 H e a d I n t e r f a c e C 7 0 0 X - L / R H R Head Interface C700X-L/R HR There are two head inter…

Appendix
Description of Boards 4.2.2 Vision board spread spectrum HCU [03067289-xx]
154 Gantry Retrofit Portalnachrüstung
4.2.2.1
4.2.2.1 DIP Switch on the Vision Board (Digital Version 02)
DIP Switch on the Vision Board (Digital Version 02)
* Not all gantries may be available, depending on the machine type.
S Gantry* Comments
1 2 3 4
1 OFF OFF OFF OFF Reset - CAN processor
2 OFF ON OFF ON PID0 address switch 1 -> gan-
try
3OFF OFF ON ONPID1 address switch 2 -> gan-
try
4 OFF OFF OFF OFF CAN R - switch for the terminal
resistor on the CAN bus
5ON ON ON ONSpeed: ON = 1 Mbit/s, OFF =
500 Kbit/s
6ON ON ON ONCAN ID - for X machine ON

Appendix
4.2.3 Head Interface C700X-L/R HR Description of Boards
Gantry Retrofit Portalnachrüstung 155
4.2.3
4.2.3 Head Interface C700X-L/R HR
Head Interface C700X-L/R HR
There are two head interface designs. Depending on the gantry, either the head interface C700X-L or
C700X-R will be used.
Standard gantry (not rotated) [03091013-01]
NOTICE
C&P20 P
If you are converting to an C&P20 P, the head interface must have at least function state -03.

Appendix
Description of Boards 4.2.3 Head Interface C700X-L/R HR
156 Gantry Retrofit Portalnachrüstung
Rotated gantry (gantry 2 and 4 at X4i S) [03091023-01]