SI-F130 Manual(EN)_jpg_ Rev1.pdf - 第158页

Ejector Setup HLF-10423-01 Ejector Setup SHEET 2/3 4 Adjust the pusher to the ORG position. 1. Loosen the p usher mounting bolts. 2. M o v e t h e p u s h e r b y h a n d s o t h a t t h e pusher left face is at the ORG …

100%1 / 310
Ejector Setup
HLF-10423-01
Ejector Setup
SHEET
1/3
Ejector Setup
[Necessary jig]
Do not use jig.
[Procedure]
1 Check that the sensor is not turned on/off
when the conveyor belt on the ORG sensor
and OT sensor (CCW) is lowered or raised
by approximately 1 mm.
The sensor does not respond even if the
ejector belt oscillates with amplitude of 1
mm.
2 Loosen the mounting bolts (2) located on the
bottom face of the pusher, and shift the
pusher in right direction by hand to tempo-
rarily fasten.
Position of the mounting bolts can be con-
firmed by placing mirror below the pusher.
3 Return the ejector to the origin.
1. Click in an order of MANUAL menuÎ
PWB TRANSPORT tabÎ
Ejector Move button.
Ejector Move screen is displayed.
2. Press the ORG button on the operation
panel with the Ejector Move screen
being displayed.
The ejector returns to the origin.
Ejector belt
ORG sensor OT sensor
Mounting bolt
Pusher
Ejector Setup
HLF-10423-01
Ejector Setup
SHEET
2/3
4 Adjust the pusher to the ORG position.
1. Loosen the pusher mounting bolts.
2. Move the pusher by hand so that the
pusher left face is at the ORG position.
3. Fasten the pusher mounting bolts to
fix the pusher.
5 After adjustment, check the ORG position.
1. Press the emergency stop switch to
turn off the servo.
2. Shift the pusher in right direction by
hand.
3. Turn the emergency stop switch in the
arrow direction to release the emer-
gency stop state.
4. Press the RESET button on the op-
eration panel.
5. Press the ORG button on the operation
panel with the Ejector Move screen
being displayed.
Check that the pusher returns to the position ad-
justed in the procedure 4.
6 Check the positions of the OT sensor (CCW)
and the mechanical stopper.
1. Press the emergency stop switch to
turn off the servo.
2. Move the pusher in left direction by
hand and check that the LED for the
OT sensor (CCW) lights up.
3. Further move the pusher in left direc-
tion and check that the pusher con-
tacts the mechanical stopper.
If the pusher contacts the mechanical stopper
prior to the OT sensor, adjust the sensor position
again.
Pusher left face
ORG
position
Pusher
ORG position
Pusher
OT sensor (CCW)
Ejector Setup
HLF-10423-01
Ejector Setup
SHEET
3/3
7 Release the emergency stop switch.
1. Return the pusher to inside (right side) from the OT sensor (CCW) responding position by
hand.
2. Turn the emergency stop switch in the arrow direction to release the emergency stop state.
3. Press the RESET button on the operation panel.
8 Check the positions of the OT sensor (CW)
and the mechanical stopper.
1. Click in an order of MANUAL menuÎ
PWB TRANSPORT tabÎ
Ejector Move button.
Ejector Move screen is displayed.
2. Click the Abs. Move button in the
Move Mode.
3. Input “475” in the Ejector Abs. Pos.
box, and press the START button on
the operation panel.
The ejector moves in right direction (to the posi-
tion of 475 mm).
4. Press the emergency stop switch to
turn off the servo.
5. Move the pusher in left direction by
hand and check that the LED for the
OT sensor (CW) lights up.
6. Further move the pusher in left direc-
tion and check that the pusher con-
tacts the mechanical stopper.
If the pusher contacts the mechanical stopper
prior to the OT sensor, adjust the sensor position
again.
OT sensor (CW)
Pusher