7 Release the emergency stop switch.
1. Return the pusher to inside (right side) from the OT sensor (CCW) responding position by
hand.
2. Turn the emergency stop switch in the arrow direction to release the emergency stop state.
3. Press the RESET button on the operation panel.
8 Check the positions of the OT sensor (CW)
and the mechanical stopper.
1. Click in an order of MANUAL menuÎ
PWB TRANSPORT tabÎ
Ejector Move button.
Ejector Move screen is displayed.
2. Click the Abs. Move button in the
Move Mode.
3. Input “475” in the Ejector Abs. Pos.
box, and press the START button on
the operation panel.
The ejector moves in right direction (to the posi-
tion of 475 mm).
4. Press the emergency stop switch to
turn off the servo.
5. Move the pusher in left direction by
hand and check that the LED for the
OT sensor (CW) lights up.
6. Further move the pusher in left direc-
tion and check that the pusher con-
tacts the mechanical stopper.
If the pusher contacts the mechanical stopper
prior to the OT sensor, adjust the sensor position
again.
OT sensor (CW)
Pusher
Adjustment of Bulk Unit Position
HLF-10424-01
Adjustment of Bulk Unit Position
SHEET
1/2
Adjustment of Bulk Unit Position
[Necessary jigs]
Bulk cassette jig
[Procedure]
1 Set the bulk cassette jig at the position of
No.20 on the cassette table.
There shall be no gap between the bulk
cassette jig and the cassette table.
Set at the same jig position (front side
No.20) as set in the “Adjustment FF/FR
Axis Feed Roller X-Direction Position”.
2 Move the XY Axis to the position of cassette
No.20.
1. Click in an order of MANUAL menuÎ
CASS. tab.
Cassette operation screen is displayed.
2. Input “120” into the Cassette Position,
and click the Move button.
“Press [START] button to start Move” is dis-
played on the message screen.
3. Press the START button on the opera-
tion panel.
XY Axis moves to the position of cassette No.20.
Bulk cassette jig
Bulk cassette jig
Adjustment of Bulk Unit Position
HLF-10424-01
Adjustment of Bulk Unit Position
SHEET
2/2
3 Raise and lower the bulk cassette jig pin to
adjust it to a position where it can be easily
inserted into the nozzle hole of the air supply
unit block.
Do not move the X and Y axes.
If the X or Y axis is moved, the positional
relation with the pickup point becomes out of
adjustment.
1. Loosen the order adjustment screws
(2-M3) to adjust to a position where
the pin can be smoothly inserted into
the nozzle hole.
2. Fasten the order adjustment screws.
3. Loosen the height adjustment screws
(2-M3) to align the nozzle end with the
upper face of the bulk cassette jig pin
unit.
4. Fasten the height adjustment screws.
If the nozzle position is not aligned even
when the above procedure is performed,
loosen the air supply block attachment
bolts (2-M4) to adjust the nozzle position.
Air supply unit block
Bulk cassette jig pin unit
Nozzle
Pin
Attachment bolt
(2-M4)
Height adjust-
ment screw
(2-M3)
Order adjustment
screw (2-M3)