Parts Camera Back Light Calibration HLF-10304-01 Parts Camera Back Light Calibration SHEET 2/3 2 Select jig No. of the transmission brightness calibration jig (filter) from the list box. 3 Click the Calibration S tart bu…

Parts Camera Back Light Calibration
HLF-10304-01
Parts Camera Back Light Calibration
SHEET
1/3
Parts Camera Back Light Calibration
[Necessary jigs]
• Transmission nozzle jig
• Transmission brightness calibration jig
[Procedure]
1 Display a Parts Back Light screen.
1. Click the Light Calibration button on
the CALIBRATION screen.
Light Calibration screen is displayed.
2. Click the Parts Back Light button on
the Light Calibration screen.
Parts Back Light screen is displayed.
Transmission brightness
calibration jig
Transmission
nozzle jig

Parts Camera Back Light Calibration
HLF-10304-01
Parts Camera Back Light Calibration
SHEET
2/3
2 Select jig No. of the transmission brightness
calibration jig (filter) from the list box.
3 Click the Calibration Start button and press
the START button on the operation panel.
The turret No.1 moves to the jig setup position.
4 Install the transmission nozzle jig to the tur-
ret No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is
not drawn out by pulling downward.
5 Install the transmission brightness calibra-
tion jig to the parts camera.
Transmission
nozzle jig
Parts Camera
Transmission
brightness
calibration jig

Parts Camera Back Light Calibration
HLF-10304-01
Parts Camera Back Light Calibration
SHEET
3/3
6 Press the START button on the operation
panel.
The turret No.1 moves to the recognition position.
7 Re-press the START button on the operation
panel.
Parts camera back light calibration is started.
After a few minutes, the calibration ends, and Lv1
values from level 1 to 8 and Gap value are displayed
on the Parts Back Light screen.
8 Check the Gap values of Level 1 to 8.
It is normal if the Gap value is within 0 to 3.
9 Click the Save button.
The Gap values of Lvl 1 to 8 are saved and the Parts
Back Light screen closes.
10 Remove the transmission brightness calibration jig and transmission nozzle jig.
1. Close the Light Calibration screen and calibration screen.
2. Click in an order of MANUAL menuÎAXIS MOTION tabÎRT button.
3. Click the Jog Move button.
4. Jog move the turret No.1 toward you by pressing the left and right cursor keys to remove
the transmission brightness calibration jig and transmission nozzle jig.