SI-F130 Manual(EN)_jpg_ Rev1.pdf - 第28页

PWB Camera Setup HLF-10204-01 PWB Camera Setup SHEET 1/4 PWB Camera Setup [Necessary jigs] • Calibration plate jig • Jig positioning pin • Nozzle jig (AF06040) [Procedure] 1 Perform the origin position return on the HI s…

100%1 / 310
Acquiring Mounting Stroke Setup
HLF-10203-01
Acquiring Mounting Stroke Setup
SHEET
3/3
6 Adjust gap between the length reference
nozzle jig and calibration plate jig.
1. Click the R.H button on the Acquiring
mounting stroke screen.
RN/H Axis screen is displayed.
2. Click the Jog Move button.
3. Press the downward cursor key and
lower until the gap between the length
reference nozzle jig and calibration
plate jig becomes 0.03mm.
Slowly lower by Jog slow move while
checking the nozzle position so that the
length reference nozzle jig does not collide
he calibration plate jig.
4. Check the gap between the length ref-
erence nozzle jig and calibration plate
jig using thickness gauge of 0.03mm.
5. After completing to adjust the gap of
0.03mm, press the Return button on
the RN/H Axis screen to return to the
Acquiring mounting stroke screen.
7 Save the H axis height (placement height).
1. Click the Save button.
The adjusted H axis height is saved and the value
of “NOZZLE_S” in calib.ini file is updated.
8 Remove the length reference nozzle jig.
1. Return to the HI screen and press the
ORG button on the operation panel.
All axes return to origin.
2. Remove the length reference nozzle jig
from the turret No.1.
Thickness gauge
Length reference
nozzle jig
PWB Camera Setup
HLF-10204-01
PWB Camera Setup
SHEET
1/4
PWB Camera Setup
[Necessary jigs]
Calibration plate jig
Jig positioning pin
Nozzle jig (AF06040)
[Procedure]
1 Perform the origin position return on the HI screen.
1. When the CALIBRATION screen is displayed, press the Return button to return to the HI
screen.
2. Press the ORG button on the operation panel.
Origin position return is performed.
2 Display PWB Camera Setup screen.
1. Click in an order of M/C SETUP menuÎM/C MAINTENANCE tabÎCalibration button.
CALIBRATION screen is displayed.
2. Click the Machine Setup button.
Machine Setup screen is displayed.
3. Click the PWB Camera Setup button.
PWB Camera Setup screen is displayed.
Calibration plate jig
Nozzle jig (AF06040)
Jig positioning pin
PWB Camera Setup
HLF-10204-01
PWB Camera Setup
SHEET
2/4
3 Install the nozzle jig (AF06040) to turret
No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is
not drawn out by pulling downward.
4 Move the turret No.1 to above nozzle in-
serting hole of the calibration plate jig.
1. Click the XY button on the PWB
Camera Setup screen.
XY Axis screen is displayed.
2. Click the Jog Move button.
3. Press the cursor key to move the turret
No.1 to above nozzle inserting hole.
4. Click the Return button to return to
the PWB Camera Setup screen.
5 Click the servo OFF button on the PWB
Camera Setup screen.
Servos for X, Y and H axes are turned off.
Nozzle jig
(AF06040)
Nozzle inserting hole
Calibration plate jig upper surface figure