Fixed Camera Rcg Heig ht Calibration HLF-10312-01 Fixed Camera Rcg Height C alibration SHEET 1/4 Fixed Camera Rcg Height Calibration [Necessary jigs] • Length reference nozzle jig • Fixed camera jig base • Thickness gaug…

100%1 / 310
Pickup Camera Calibration
HLF-10311-01
Pickup Camera Calibration
SHEET
5/5
15 Press the START button on the operation
panel.
Turret No.1 moves to the nozzle installing position
and “Remove the pickup check nozzle” is displayed
on the message screen.
16 Remove the length reference nozzle jig and
press the START button on the operation
panel.
The message screen closes and returns to the Pickup
Camera Calibration screen.
17 Click the Save button on the Pickup Camera
Calibration screen.
Calibration information is saved and the Pickup Cam-
era Calibration screen closes.
In order to store the calibration result in
the unit, be sure to re-start the unit before
operating the unit.
Fixed Camera Rcg Height Calibration
HLF-10312-01
Fixed Camera Rcg Height Calibration
SHEET
1/4
Fixed Camera Rcg Height Calibration
[Necessary jigs]
Length reference nozzle jig
Fixed camera jig base
Thickness gauge (t=0.01 mm)
[Procedure]
1 Press the emergency stop switch to turn off the servo.
2 Turn off the interlock switch and open the rear door.
3 Unscrew the 6 screws and remove the
shooter on the rear side of the unit.
4 Unscrew the 2 cap screws to remove the
cover on the rear of the fixed camera.
Length reference
nozzle jig
Fixed camera jig base
Thickness gauge
Shooter
Cove
r
Fixed camera
Fixed Camera Rcg Height Calibration
HLF-10312-01
Fixed Camera Rcg Height Calibration
SHEET
2/4
5 Secure the fixed camera jig base with 2
screws.
6 Turn the emergency stop switch in the arrow direction to release the emergency stop state.
7 Perform the origin position return.
1. Press the RESET button on the operation panel to perform the initialization.
2. When “SYMC Initialize End” is displayed on the screen, press the FRONT button to turn
ON the servo.
3. Press the ORG button on the operation panel to start the origin position return.
When the origin position return is completed, the ORG button goes off.
8 Display a Fixed Camera Rcg Height screen.
1. Click in an order of M/C SETUP
menuÎM/C MAINTENANCE tabÎ
Calibration button.
2. Click the Fixed Camera Rcg Height
button on the CALIBRATION screen.
Fixed Camera Rcg Height screen is displayed.
9 Click the Rcg Height Start button.
“Install nozzle?” is displayed on the message
screen.
Fixed camera jig base