Fixed Camera Middl e Light Calibration HLF-10306-01 Fixed Camera Middle Li ght Calibration SHEET 1/2 Fixed Camera Middle Light Calibration [Necessary jigs] • Fixed camera light calibration jig [Procedure] 1 Display a Fix…

Fixed Camera Upper Light Calibration
HLF-10305-01
Fixed Camera Upper Light
Calibration
SHEET
3/3
6 Click the Save button.
The Gap values of Lvl 1 to 8 are saved and the Fixed
Camera Upper Light screen closes.

Fixed Camera Middle Light Calibration
HLF-10306-01
Fixed Camera Middle Light
Calibration
SHEET
1/2
Fixed Camera Middle Light Calibration
[Necessary jigs]
• Fixed camera light calibration jig
[Procedure]
1 Display a Fixed Camera Upper Light screen.
1. Click the Light Calibration button on
the CALIBRATION screen.
Light Calibration screen is displayed.
2. Click the Fixed Camera Middle Light
button on the Light Calibration screen.
Fixed Camera Middle Light screen is displayed.
Each Fixed Camera Light button on the
right of the Light Calibration menu be-
comes effective in case of fixed camera
specification device.
Fixed camera light calibration jig

Fixed Camera Middle Light Calibration
HLF-10306-01
Fixed Camera Middle Light
Calibration
SHEET
2/2
2 Select jig No. of fixed camera light
calibration jig from the list box.
3 Click the Calibration Start button.
“Install calibration jig for fixed light. Press [START]
to start light calibration” is displayed on the message
screen.
Unless the fixed camera light calibration
jig is set, install it according to the proce-
dure 4 of the previous “Fixed Camera Up-
per Light Calibration”.
4 Fixed camera middle light calibration is started.
1. Press the START button on the operation panel.
Calibration is started.
After a few minutes, the calibration ends, and “Remove calibration jig for fixed light” is displayed on the message
screen.
2. Click the OK button to close the message screen.
If fixed camera light calibration is subsequently performed, it is unnecessary to remove the
fixed camera light calibration jig.
5 Click the Save button.
The Gap values of Lvl 1 to 8 are saved and the Fixed
Camera Middle Light screen closes.