Software Limit Setup HLF-10315-01 Soft w are Limit Setup SHEET 4/7 9. Press the RESET butt on on the op- eration panel to c ancel the alarm dis - play . 10. Make a me mo of the X position data of X-CCW displayed on the A…

100%1 / 310
Software Limit Setup
HLF-10315-01
Software Limit Setup
SHEET
3/7
2 Check the X position data of over-travel
sensor (OT) of X-CCW.
1. Click in an order of MANUAL menu
ÎCASS. tab.
Cassette operation screen is displayed.
2. Input “101” into the cassette position
input box and click the Move button.
The head moves to the cassette position “101”.
3. Click in an order of AXIS MOTION
tabÎXY button.
XY Axis screen is displayed.
4. Click the Rel. Move button.
5. Click the X Axis button in the Rel.
Move.
6. Input “-3.000” into number input box
for X axis and press the START button
on the operation panel.
The X axis relatively moves from the position of
cassette 101 by -3mm.
7. Click the Jog Move button.
8. Press the left cursor key one time by
one by slow Jog Move to move the X
axis in negative direction.
When the X axis is moved to the over-travel po-
sition, alarm is displayed.
Software Limit Setup
HLF-10315-01
Software Limit Setup
SHEET
4/7
9. Press the RESET button on the op-
eration panel to cancel the alarm dis-
play.
10. Make a memo of the X position data of
X-CCW displayed on the AXIS
MOTION screen.
11. Press the ORG button on the operation
panel to perform origin position re-
turn.
3 Check the Y position data of over-travel
sensor (OT) of Y-CW.
1. Click the CASS. tab.
Cassette operation screen is displayed.
2. Input “101” into the cassette position
input box and click the Move button.
The head moves to the cassette position “101”.
3. Click in an order of AXIS MOTION tab
ÎXY button.
XY Axis screen is displayed.
4. Click the Rel. Move button.
5. Click the Y Axis button in the Rel.
Move.
6. Input “-1.500” into number input box
for Y axis and press the START button
on the operation panel.
The Y axis relatively moves from the position of
cassette 101 by -1.5mm.
Software Limit Setup
HLF-10315-01
Software Limit Setup
SHEET
5/7
7. Click the Jog Move button.
8. Press the left cursor key one time by
one by slow Jog Move to move the Y
axis in negative direction.
When the Y axis is moved to the over-travel posi-
tion, alarm is displayed.
9. Press the RESET button on the op-
eration panel to cancel the alarm dis-
play.
The alarm disappears and the screen returns to
the AXIS MOTION screen.
10. Make a memo of the Y position data of
Y-CW displayed on the AXIS MOTION
screen.
11. Press the ORG button on the operation
panel to perform origin position re-
turn.
4 Check the XY position data of over-travel
sensors (X-CW, Y-CCW) in the same pro-
cedures as that of the procedures 2 to 3.
Nozzle moving area
OT boundary
Pickup position area
X axis
X-CW
Y axis
X-CCW
Y-CCW
Y-CW
Z240
Z201
Z101
Z140