3-20 TM-401 User’s Guide Taper Tab D292104.6.fm The third T aper Setup screen focuses on Sealer Settings . It will vary in appearance depending on the type of sealer selected. In th e example below , the selected Seal T …

D292104.6.fm Taper Tab
Chapter 3: Human Machine Interface 3-19
The Continuous Advance button advances the tape through the Taper and onto
the take-up reel. It will continue to advance until Continuous Advance is pressed
a second time.
Note: Continuous Advance is useful for creating a trailer or loading tape at the begin-
ning of a job.
Pressing the right Arrow button opens the next Taper Setup screen which focuses on Vision
Setup.
A. The Camera State button toggles between ON ( I ) and OFF (O).
The Parts Until Inspection value is the number of pockets between the Place
point and the Inspection point. Begin the count at the Place position at zero, so
the Place position is not included.
B. Pressing the Trigger button triggers the 2D Camera to inspect the part which is
currently at the Inspection point. The box to the right of the Trigger button will dis-
play a green PASS message or a red FAIL message.
Note: For more detailed inspection configuration and procedures, see the Cognex
Checker User’s Guide which was included with the TM-401.
Pressing the right Arrow button opens the next Taper Setup screen.
Taper Screen 2
A
B
Downloaded from www.Manualslib.com manuals search engine

3-20 TM-401 User’s Guide
Taper Tab D292104.6.fm
The third Taper Setup screen focuses on Sealer Settings. It will vary in appearance depending on
the type of sealer selected. In the example below, the selected Seal Type is Heat.
A. The Seal Type button toggles between Heat seal and PSA seal.
The Dwell Time field is only active when heat seal is ON. Dwell time refers to the
amount of time that the Heat Seal Shoes are in contact with the Cover Tape.
Enter the desired dwell time in milliseconds in this field.
The Manual Seal button activates the sealer to perform one seal.
B. The Set Point field allows the user to select the Heat Sealer set point, or target
temperature. Press the field to open the keypad, then enter the desired tempera-
ture in degrees Celsius.
The Measured field shows the current Heat Sealer temperature in degrees Cel-
sius.
Note: The TM-401 accommodates a wide range of carrier tapes and cover tapes. Set-
tings may vary from one tape product to another. The recommended starting point is 90°
C. The maximum recommended operating temperature is 160° C. The temperature for
each seal shoe should be increased or decreased as needed after running a peel force
test.
Taper Screen 3
A
B
Downloaded from www.Manualslib.com manuals search engine

D292104.6.fm Taper Tab
Chapter 3: Human Machine Interface 3-21
Pressing the right Arrow button in the third Taper Setup screens opens the final Taper Setup
screen. The fourth Taper Setup screen focuses on Leader and Sensor settings.
A. The Tape Jam Sensor ON ( I ) or OFF (O) button turns the Tape Jam Sensor on
and off. The Tape Jam Sensor registers a tape jam whenever something pro-
trudes above the top of the carrier tape pocket. This might be caused by a mis-
placed part, a pocket that has been loaded with two parts or by a buckle in the
tape.
When the Tape Jam Sensor is activated, the job that is being run is paused and an
error message appears on the HMI screen. The recommended setting for the
Tape Jam Sensor is ON.
The Low Cover Sensor ON ( I ) or OFF (O) button turns the Low Cover Tape Sen-
sor on and off. The Low Cover Tape Sensor detects when the cover tape reel is
running low. When the Low Cover Tape Sensor is activated, an error message
appears on the HMI screen. The recommended setting for the Low Cover Tape
Sensor is ON.
Note: The Low Cover error message is only displayed once during a job.
B. When Leader State is ON ( I ), the TM-401 will create a leader of the specified
length at the end of the job.
The Leader Length field is only active when Leader State is ON. Enter the
desired leader length in millimeters in the field.
Note: The TM-401 will use these settings for the current job. To save Taper Settings for
future jobs, go to the Job Tab, select a job name and Save. If settings are not saved, all
data is lost when the TM-401 is powered off.
Taper Screen 4