4-14 TM-401 User’s Guide Configure HMI Settings D292104.7a.fm 3 .E N T E R JOB P ARAME TERS . a. Enter Job Quantity b. Enter Job Description . Press the right Arrow key to open the next Job W izard screen . 4. T APER SET…

100%1 / 292
D292104.7a.fm Configure HMI Settings
Chapter 4: Setup 4- 13
Configure HMI Settings
The TM-401’s Job Wizard leads the user through the HMI setup process.
1. OPEN JOB WIZARD
a. Open the HMI Job Screen.
b. Press the Job Wizard button to open the Job Wizard.
2. RESET JOB
a. Press Reset Job to initialize system for Job Wizard.
b. Press the right Arrow key to open the next Job Wizard screen.
Step 6:
Setup
HMI
Downloaded from www.Manualslib.com manuals search engine
4-14 TM-401 User’s Guide
Configure HMI Settings D292104.7a.fm
3.ENTER JOB PARAMETERS.
a. Enter Job Quantity
b. Enter Job Description. Press the right Arrow key to open the next Job Wizard
screen.
4. TAPER SETUP
Enter Pitch, Seal Type and Dwell Time.
Step 6:
Setup HMI
TA P ER
Downloaded from www.Manualslib.com manuals search engine
D292104.7a.fm Configure HMI Settings
Chapter 4: Setup 4- 15
a. Enter the correct tape pitch for the carrier
tape that will be run. If unsure, use the
Pitch Setting Guide on the Taper to
determine the pitch.
b. Select PSA or Heat Seal.
c. If Heat Seal is enabled, enter the desired
temperature in degrees Celsius for both
the Inner and Outer Sealer Temperature
Settings. Allow the heat sealer to reach
its operating temperature before
continuing.
Note: The TM-401 accommodates a wide
range of carrier tapes and cover tapes. Set-
tings may vary from one tape product to
another. The recommended starting point is
90° C. The maximum recommended operat-
ing temperature is 160° C. The temperature
for each seal shoe should be increased or
decreased as needed after running a peel
force test.
d. Set the heat shoe Seal Pressure to the
appropriate setting. This setting controls
the amount of force applied when the
sealer shoes drop. The recommended
starting point is 50 psi.
e. Press the Continuous Advance button.
The taping module will begin the advance
of the carrier tape and cover tape through
the sealer. The cover tape will be sealed
onto the carrier tape as it advances.
f. Observe whether the sealer’s width is
adjusted correctly for the cover tape. It
should seal just inside the outside edges
of the carrier tape without going off the
edges or over the pockets. If it is not, stop
the taper by pressing the Continuous
Advance button again.
Step 6:
Setup HMI
TA P ER