编带机说明书-含图纸tm401.pdf - 第97页
D292104.7a.fm Configure HMI Settings Chapter 4: Setup 4- 23 set at the Place position.. a. T o manually set the Place Actuator to the correct nozzle height, press Place Extend b. Use a 2.5mm hex wrench to hold the Actuat…

4-22 TM-401 User’s Guide
Configure HMI Settings D292104.7a.fm
10. Set Place Position
a. Use the Arrow keys to position the Pick Head and Carrier Tape so the Nozzle
is centered over the carrier tape placement position.
The Up/Down Arrow keys move the Pick Head forward and backward. The
Left/Right Arrow keys move the tape left and right in the Taper Track.
b. When the Nozzle is centered over the tape pocket, press Set Place Position
to set the position.
c. Press the right Arrow Key to move to the next Job Wizard screen.
11. Set Place Nozzle Height The Pick Head’s Z Axis (up/down) position needs to be
Step 6:
Setup HMI
NOZZLE
Downloaded from www.Manualslib.com manuals search engine

D292104.7a.fm Configure HMI Settings
Chapter 4: Setup 4- 23
set at the Place position..
a. To manually set the Place Actuator to
the correct nozzle height, press Place
Extend
b. Use a 2.5mm hex wrench to hold the
Actuator Adjustment Screw in place
from the bottom, while loosening the
Jam Nut on top of the Actuator
Adjustment Screw with an 8mm open
ended wrench. Lower the Nozzle until
the part is barely touching the top of
the pocket in the Place Location.
c. Tighten the Jam Nut.
d. Press Place Retract to retract the Nozzle to a safe height.
e. Press the right Arrow Key to move to the next Job Wizard screen.
Downloaded from www.Manualslib.com manuals search engine

4-24 TM-401 User’s Guide
Configure HMI Settings D292104.7a.fm
12. Set Rotation Angle
a. Enter the placement angle which was manually set in Step 7. The options are
0, -90 and +90.
• If rotation is set at 0,
the part will be placed
in the same orientation
as it was picked.
• If rotation is set at -90,
the part will be rotated
90 degrees clockwise
prior to placement.
• If rotation is set at +90,
the part will be rotated
90 degrees counter-
clockwise prior to
placement.
b. Press the right Arrow Key to move to the next Job Wizard screen.
Step 6:
Setup HMI
NOZZLE
-90
0
+90
Rotation Options
Downloaded from www.Manualslib.com manuals search engine