4OM-1625-004_w.pdf - 第122页
4OM-1603 2-3 2. Management Information : Chap.2 1012-005 • Remedial Procedure from “Management Information” Window (1) Make a note of the management information. Notice If you forget the Management Information, correct …

4OM-1603
2-2
2. Management Information : Chap.2
2. Management Information
2.1 "Management Information" Window
When normal recovery does not occur after a mistake in the machine operation or
an error, the following management information window appears.
[1]
[4]
[3]
[2]
[5]
Example of Management Information F4B2
[1] Management Information
In this window, the management information is displayed.
[2] Management Information Code
In this window, the management information code is displayed.
[3] Display Area A
The outline of the management information is displayed in this area.
[4] Display Area B
The details of the management information are displayed in this area.
[5] [OK] Button
When this button is pressed, the window displayed just prior to the
"Management Information" is returned.
1012-005

4OM-1603
2-3
2. Management Information : Chap.2
1012-005
•
Remedial Procedure from “Management Information” Window
(1) Make a note of the management information.
Notice
If you forget the Management Information, correct recovery can not be
performed. Therefore, make sure to make a note.
(2) Press the [OK] button to return the original window.
(3) Perform the correct recovery based on the Management Information.

4OM-1603
2-4
2. Management Information : Chap.2
2.2 Management Information List
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
010101
Emergency Stop
Press [POWER ON] button to activate Load Power circuit.
010103
Emergency Stop
Emergency Stop switch is pressed. Please cancel it.
010201
Air Pressure Drop
Detection of Air Pressure Drop is detected
010401
Safetycoverlockconrm
Please close and lock the safety cover.
010402
Safetycoverlockconrm
Operate after close and lock the safety cover. (LED on)
010403
Safetycoverlockconrm
Operate after close and lock the safety cover.
010404
Safetycoverlockconrm
The safety cover is in unlock. Please complete to unlock and operate it.
010503
Beam XY main loop OFF
Beam XY main circuit Error
010801
Feederbaseconrm(Rear)
Set the feeder cart (rear) and connect cable.
010802
Feederbaseconrm(Rear)
Detect elevator unit (rear).
Operate after remove elevator .
010803
Feederbaseconrm(Rear)
Could not detect elevator unit (rear).
Connect elevator unit and operate by "unit exchange menu".
010804
Feederbaseconrm(Rear)
Disconnect elevator unit (rear).
Check connector.
010805
Feederbaseconrm(Rear)
Feeder cart (rear) is not upper position.
Push feeder ready sw.
010806
Feederbaseconrm(Rear)
Push feeder ready sw.
010807
Feederbaseconrm(Rear)
Feeder base power or Feeder power is "OFF". Please press "Feeder Ready"
switch(Rear), and put it up again after putting Feeder Cart(Rear) down.
010901
Feederbaseconrm(Front)
Set the feeder cart (front) and connect cable.
010902
Feederbaseconrm(Front)
Detect elevator unit (front).
Operate after remove elevator .
010903
Feederbaseconrm(Front)
Could not detect elevator unit (front).
Connect elevator unit and operate by "unit exchange menu".