050402 Manual transfer
Please operate after removing P.C.B. from output conveyor. There is a possibility
of pushing and rising with Stopper.
050403 Manual transfer
It is impossible to take from Sensor Detection of Input Position.
Please put P.C.B. on Input Conveyor, or move it to Output position in Recovery
Menu.
050404 Manual transfer
PCB (X>260mm) which is set by PP data is unable to be taken in Input Conveyor.
050405 Manual transfer
There is PCB on Deceleration Sensor of Input Conveyor. There is a possibility that
PCB is inserted.
050406 Manual transfer
There is PCB on Deceleration Sensor of Shuttle Conveyor in Output side. There
is a possibility that PCB is inserted.
050407 Manual transfer
Lane A is not able to be set in Current Program. Please change Current Program
or change to Lane B.
050408 Manual transfer
Lane B is not able to be set in Current Program. Please change Current Program
or change to Lane A.
050409 Manual transfer
PCB Y size and Conveyor Width in Current Program are not equal. Please change
Current Program.
050501 Convert Width Setup
Please set conveyor width 49.5mm 461.5mm.
The total of P.C.B. size/offset/clearance is over movable range.
050502 Convert Width Setup
Please set conveyor width 49.5mm 382.5mm.
The total of P.C.B. size/offset/clearance is over movable range.
050503 Convert Width Setup
Movable Range for the destination of W1 is set.
Please check P.C.B. size/offset/clearance of Lane A.
050504 Convert Width Setup
Movable Range for the destination of W1 is set.
Please check P.C.B. size/offset/clearance of Lane A.
050505 Convert Width Setup
Movable Range for the destination of W2 is set.
Please check P.C.B. size/offset/clearance of Lane A
050506 Convert Width Setup
Movable Range for the destination of W2 is set.
Please check P.C.B. size/offset/clearance of Lane A.
050507 Convert Width Setup
Movable Range for the destination of W3 is set.
Please check P.C.B. size/offset/clearance of Lane B.
4OM-1603
2-17
2. Management Information : Chap.2
1012-005
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
050508 Convert Width Setup
Movable Range for the destination of W3 is set.
Please check P.C.B. size/offset/clearance of Lane B.
050509 Convert Width Setup
These is a possibility of the interference with W1 and W2.
Please check P.C.B. size/offset/clearance of Lane A.
05050a Convert Width Setup
There is a possibility of the interference with W2 and W3. Please Check P.C.B.
size/offset/clearance of Lane A/B.
05050b Convert Width Setup
There is an interference between object position of Conveyor and Support Pin.
Please exchange Support Pin.
050601 Middle Conveyor
Rotation Direction set of Middle Conveyor in supply side differs from Main Device
transfer direction. Please change the rotation direction of Middle conveyor.
050602 Middle Conveyor
Emergency Stop switch of middle conveyor in supply side is pressed.
Please cancel it.
050603 Middle Conveyor
Safety Cover of middle conveyor in supply side is open. Please close it.
050604 Middle Conveyor
Input Machine communication mode is set [PUSHER].
Cannot use [PUSHER] mode when Middle Conveyor is contacted.
050611 Middle Conveyor
Rotation Direction set of Middle Conveyor in output side differs from Main Device
transfer direction. Please change the rotation direction of Middle conveyor.
050612 Middle Conveyor
Emergency Stop switch of middle conveyor in output side is pressed.
Please cancel it.
050613 Middle Conveyor
Safety Cover of middle conveyor in output side is open. Please close it.
050701 Shuttle Conveyor
Emergency Stop Switch of Shuttle Conveyor in Input side is pressed. Please
cancel it.
050702 Shuttle Conveyor
The safety cover of Shuttle Conveyor in Input side is open. Please close it.
050703 Shuttle Conveyor
Deceleration sensor of Shuttle Conveyor in Input side is detected. Please remove
PCB because there is a possibility that it is inserted.
050704 Shuttle Conveyor
Deceleration Sensor of Input Conveyor is detected. Please remove PCB because
there is a possibility that it is inserted.
050705 Shuttle Conveyor
Deceleration Sensor of Input Conveyor in Lane A is detected. Please remove PCB
because there is a possibility that it is inserted.
4OM-1603
2-18
2. Management Information : Chap.2
1012-005
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
050706 Shuttle Conveyor
Deceleration Sensor of Input Conveyor in Lane B is detected. Please remove
PCB because there is a possibility that it is inserted.
050707 Shuttle Conveyor
Set Value of Delivery Position of Device System/Input Machine PCB is not in the
Movable Range. Please set the value 467mm and less whose value is the sum
with Y size of PCB.
050708 Shuttle Conveyor
Please set [SMEMA] Mode for Device System/Input Machine Output. And, Please
conrmthatInp/OutpMachineSignalis
setas[Enable].
050709 Shuttle Conveyor
Please set the same value in Lane A / Lane B of Delivery Position of Device
System/Input Machine PCB.
050711 Shuttle Conveyor
Emergency Stop Switch of Shuttle Conveyor in Output side is pressed. Please
cancel it.
050712 Shuttle Conveyor
The safety cover of Shuttle Conveyor in Output side is open. Please close it.
050713 Shuttle Conveyor
Deceleration Sensor of Shuttle Conveyor in Output side is detected. Please
remove PCB there is a possibility that it is inserted.
050714 Shuttle Conveyor
Stop Sensor of Output Conveyor is detected. Please remove PCB there is a
possibility that it is inserted.
050715 Shuttle Conveyor
Stop Sensor of Output Conveyor in Lane A is detected. Please remove PCB there
is a possibility that it is inserted.
050716 Shuttle Conveyor
Stop Sensor of Output Conveyor in Lane B is detected. Please remove PCB there
is a possibility that it is inserted.
050717 Shuttle Conveyor
Set Value of Delivery Position of Device System/Output Machine PCB is not in the
Movable Range. Please set the value 467mm and less whose value is the sum
with Y size of PCB.
050718 Shuttle Conveyor
Please set [SMEMA] Mode for Device System/Output Machine Output. And,
Please
conrmthatInp/OutpMachineSignal
issetas[Enable].
060101 Feeder communication Error
Can not have communication with Feeder. Is Feeder selected Feeder No.
inserted?
060201 Feeder type Error
Library and Feeder are not the same.
060301 Feeder preparation Error
Make Feeder base dropped once. Then, rise it again.
060401 Feeder No. Error
The Feeder is not pickup. Please select another one.