4OM-1603 1-19 3. Maintenance Spots : Chap.1 1003-003 3.2.2 V acuum System V acuum Pressure Every Day Inspection Required T ime: 1 minute Check the vacuum pressure visually . V acuum V alve Fully Closed: Min. -93 kPa (Min…

100%1 / 347
4OM-1603
1-18
3. Maintenance Spots : Chap.1
1012-004
Filter
Every 3 Months Cleaning
(1) Detach the air filter.
Turn the cover unit in the direction shown in the figure, using the air-filter case
removing jig to remove the cover.
(2) While rotating the filter holder counterclockwise, pull it out.
(3) Pull out the filter and blow air to it for cleaning.
(4) Insert the filter back in place and turn the filter holder clockwise to attach.
(5) Attach the filter cover.
When the filter has become defective, replace it with a new one.
Filter Holder
Note
Required Time: 5 minutes
F4A9
4OM-1603
1-19
3. Maintenance Spots : Chap.1
1003-003
3.2.2 Vacuum System
Vacuum Pressure
Every Day Inspection
Required Time: 1 minute
Check the vacuum pressure visually.
Vacuum Valve Fully Closed:
Min. -93 kPa (Min. 70 cmHg) or more
Running:
Min. -60 kPa (Min. 45 cmHg) or more
When the vacuum pressure is insufficient, air
may be leaking from the vacuum line or the
vacuum pump may have broken down.
F4A10
C
Filter Case
Filter
Every 3 Months Cleaning
(1)
(2)
(3) Blow air to the filter for cleaning.
(4) Attach the cover and tighten the setscrews.
If a clearance is left between the main machine and the cover,
the tape will pop out from the clearance during the operation,
causing the machine to breakdown or generate an error.
Required Time: 10 minutes
Remove four setscrews fastening the cover located at the lower area of the
front side of the machine and detach the cover.
Rotate the filter case in Arrow Direction C to detach and then take out the
filter.
When the vacuum pressure has dropped during the operation,
replace the filter with a new one.
Notice
Note
F4A11
4OM-1603
1-20
3. Maintenance Spots : Chap.1
1007-003
3.2.3 Component Recognition Camera Section
Notice
Be sure to use a suction force such as a vacuum cleaner for the
cleaning.
Do not blow air to any cleaning section with an air gun.
When air is blown, the dirt and dust inside the machine will disperse,
causing the recognition system and the machine to malfunction.
Component Recognition Camera
(2 locations)
Every Day Cleaning
Required Time: 4 minutes
Remove the components that have fallen with a
pair of vacuum tweezers and wipe off dust with
a lens cleaning cloth.
F4A12
Note
G -S047-01 Adhesive Cleaner (Part No: 226J2091) is also available as an option
Adhesive Cleaner
F4A13