4OM-1625-004_w.pdf - 第298页
4OM-1603 3-143 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 604408 T eaching Height of Stocker Master Error in calculating drive wave of NL-axis ----- 604409 T eaching…

4OM-1603
3-142
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604312 Chute(For Head exchange) teaching Height
Program Error
-----
604313 Chute(For Head exchange) teaching Height
Offset is 1mm less than the set value.
-----
604314 Chute(For Head exchange) teaching Height
Offset is 1mm more than the set value.
-----
604315 Chute(For Head exchange) teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604316 Chute(For Head exchange) teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604317 Chute(For Head exchange) teaching Height
There
isnomeasureddataof
Noz1.ItisnecessarytomeasureNoz1rst.
-----
604318 Chute(For Head exchange) teaching Height
CannotmeasureitforXY-coord
isnotdened.
-----
604319 Chute(For Head exchange) teaching Height
Error in Flowing Quantity
-----
604401 Teaching Height of Stocker Master
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604402 Teaching Height of Stocker Master
Time-out of [OFF] signal of Linear measure sensor
-----
604403 Teaching Height of Stocker Master
Error in DD-axis
-----
604404 Teaching Height of Stocker Master
Error in NS-axis
-----
604405 Teaching Height of Stocker Master
Error in DD/NS-axis
-----
604406 Teaching Height of Stocker Master
Time-out of DD/NS-axis
-----
604407 Teaching Height of Stocker Master
Error in calculating drive wave of HL-axis
-----
1012-005

4OM-1603
3-143
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604408 Teaching Height of Stocker Master
Error in calculating drive wave of NL-axis
-----
604409 Teaching Height of Stocker Master
Time-out of starting HL/NL-axis movement
-----
60440a Teaching Height of Stocker Master
Time-out of starting HL-axis movement
-----
60440b Teaching Height of Stocker Master
Time-out of starting NL-axis movement
-----
60440c Teaching Height of Stocker Master
T
ime-outofnishingHL/NL-axismovement
-----
60440d
Teaching Height of Stocker Master
Failed in measuring real time of linear measure sensor.
-----
60440e Teaching Height of Stocker Master
Error in measuring Linear measure sensor
-----
60440f Teaching Height of Stocker Master
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604410 Teaching Height of Stocker Master
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604411 Teaching Height of Stocker Master
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604412 Teaching Height of Stocker Master
Program Error
-----
604413 Teaching Height of Stocker Master
Offset is 1mm less than the set value.
-----
604414 Teaching Height of Stocker Master
Offset is 1mm more than the set value.
-----
604415 Teaching Height of Stocker Master
The value of Flowmeter is higher than 5.0V.
-----
604416 Teaching Height of Stocker Master
The value of Flowmeter is lower than 4.7V.
-----
1012-005

4OM-1603
3-144
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604417 Teaching Height of Stocker Master
Thereisnomeasureddataof
Noz1.ItisnecessarytomeasureNoz1rst.
-----
604418 Teaching Height of Stocker Master
CannotmeasureitforXY-coord
isnotdened.
-----
604419 Teaching Height of Stocker Master
Error in Flowing Quantity
-----
604501 Teaching Pickup-Height
Error is detected before starting Detection on Linear Measure Sensor. (There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604502 Teaching Pickup-Height
Time-out of [OFF] signal of Linear measure sensor
-----
604503 Teaching Pickup-Height
Error in DD-axis
-----
604504 Teaching Pickup-Height
Error in NS-axis
-----
604505 Teaching Pickup-Height
Error in DD/NS-axis
-----
604506 Teaching Pickup-Height
Time-out of DD/NS-axis
-----
604507 Teaching Pickup-Height
Error in calculating drive wave of HL-axis
-----
604508 Teaching Pickup-Height
Error in calculating drive wave of NL-axis
-----
604509 Teaching Pickup-Height
Time-out of starting HL/NL-axis movement
-----
60450a Teaching Pickup-Height
Time-out of starting HL-axis movement
-----
60450b Teaching Pickup-Height
Time-out of starting NL-axis movement
-----
60450c Teaching Pickup-Height
T
ime-outofnishingHL/NL-axismovement
-----
1012-005