4OM-1625-004_w.pdf - 第237页
4OM-1603 3-82 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 49078C Nozzle set up Exchanging Noz has not started within predetermined time ----- 49078D Nozzle set up Exc…

4OM-1603
3-81
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49077D Nozzle set up
RecognizingNozStockerMarkhasnot
nishedwithinpredeterminedtime.
-----
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
RecognizationoftheexistenceofNoz
hasnotnishedwithinpredeterminedtime
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
RecognizingNozIDhasnotnished
withinpredeterminedtime
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting linear Measure detect
-----
490786 Nozzle set up
Time-out of reading out the result of Linear Measure detect
-----
490787 Nozzle set up
Error in the result of Linear Measure detect
-----
490788 Nozzle set up
Time-out of starting linear Measure detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Linear Measure detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Linear Measure detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
1012-005

4OM-1603
3-82
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
49078D Nozzle set up
ExchangingNozhasnotnishedwithin
predeterminedtime
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
490801 Program -change linked operation
Program-change
linkedoperationhasnotnished
withinappointedtime.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
ConrmresetMethodofdetailedSub-system
errorcountsofAlarm.
1012-005

4OM-1603
3-83
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
496102 Conveyor Width W1 Error
Conveyor Width W1-axis could not start
A state in which the operating command is not normally accepted.
1. Conrmconnectiontocommunicationcable.
2. Conrm
Powersupply(24V).
3. ConrmthecommunicationsettingofPCIboard.
4. Conrmtheaddressofdriverandcommunicationratesetting.
496110 Conveyor Width W1 Error
System setup of Conveyor Width W1 is not completed.
Driver has not completed the parameter setup yet. It is a situation in which a
correct setup has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
496111 Conveyor Width W1 Error
Zeroing Error in Conveyor Width W1
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
496112 Conveyor Width W1 Error
Out-of-Control in Conveyor Width W1
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure
motor Error.
496113 Conveyor Width W1 Error
Error in Motor Power voltage of Conveyor Width W1
Motor power voltage dropped. Check out the Power supply line(48V Line)
496114 Conveyor Width W1 Error
STP input in Conveyor Width W1 was detected
STP input is detected. The function to stop motor by Hard signal.
496115 Conveyor Width W1 Error
Over-current in Conveyor Width W1
Error in Motor output line. Check out the motor wiring,
496116 Conveyor Width W1 Error
Limit Sensor(+) was detected in Conveyor Width W1.
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
496117 Conveyor Width W1 Error
Limit Sensor(-) was detected in Conveyor Width W1.
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
496118 Conveyor Width W1 Error
Motor Disconnection of Conveyor Width W1 was detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
496119 Conveyor Width W1 Error
Control Power Voltage of Conveyor Width W1 has error
Control power for driver dropped. Check out the Power supply line.(24V Line)
1012-005