4OM-1625-004_w.pdf - 第296页
4OM-1603 3-141 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 604303 Chute(For Head exchange) teaching Height Error in DD-axis ----- 604304 Chute(For Head exchange) teac…

4OM-1603
3-140
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
60420d Chute(For adjustment when shipping up) Teaching Height
Failed in measuring real time of linear measure sensor.
-----
60420e Chute(For adjustment when shipping up) Teaching Height
Error in measuring Linear measure sensor
-----
60420f Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604210 Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604211 Chute(For adjustment when shipping up) Teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604212 Chute(For adjustment when shipping up) Teaching Height
Program Error
-----
604213 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm less than the set value.
-----
604214 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm more than the set value.
-----
604215 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604216 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604217 Chute(For adjustment when shipping up) Teaching Height
There
isnomeasureddataof
Noz1.ItisnecessarytomeasureNoz1rst.
-----
604218 Chute(For adjustment when shipping up) Teaching Height
CannotmeasureitforXY-coord
isnotdened.
-----
604219 Chute(For adjustment when shipping up) Teaching Height
Error in Flowing Quantity
-----
604301 Chute(For Head exchange) teaching Height
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604302 Chute(For Head exchange) teaching Height
Time-out of [OFF] signal of Linear measure sensor
-----
1012-005

4OM-1603
3-141
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604303 Chute(For Head exchange) teaching Height
Error in DD-axis
-----
604304 Chute(For Head exchange) teaching Height
Error in NS-axis
-----
604305 Chute(For Head exchange) teaching Height
Error in DD/NS-axis
-----
604306 Chute(For Head exchange) teaching Height
Time-out of DD/NS-axis
-----
604307 Chute(For Head exchange) teaching Height
Error in calculating drive wave of HL-axis
-----
604308 Chute(For Head exchange) teaching Height
Error in calculating drive wave of NL-axis
-----
604309 Chute(For Head exchange) teaching Height
Time-out of starting HL/NL-axis movement
-----
60430a Chute(For Head exchange) teaching Height
Time-out of starting HL-axis movement
-----
60430b Chute(For Head exchange) teaching Height
Time-out of starting NL-axis movement
-----
60430c Chute(For Head exchange) teaching Height
T
ime-outofnishingHL/NL-axismovement
-----
60430d
Chute(For Head exchange) teaching Height
Failed in measuring real time of linear measure sensor.
-----
60430e Chute(For Head exchange) teaching Height
Error in measuring Linear measure sensor
-----
60430f Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604310 Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604311 Chute(For Head exchange) teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
1012-005

4OM-1603
3-142
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604312 Chute(For Head exchange) teaching Height
Program Error
-----
604313 Chute(For Head exchange) teaching Height
Offset is 1mm less than the set value.
-----
604314 Chute(For Head exchange) teaching Height
Offset is 1mm more than the set value.
-----
604315 Chute(For Head exchange) teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604316 Chute(For Head exchange) teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604317 Chute(For Head exchange) teaching Height
There
isnomeasureddataof
Noz1.ItisnecessarytomeasureNoz1rst.
-----
604318 Chute(For Head exchange) teaching Height
CannotmeasureitforXY-coord
isnotdened.
-----
604319 Chute(For Head exchange) teaching Height
Error in Flowing Quantity
-----
604401 Teaching Height of Stocker Master
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604402 Teaching Height of Stocker Master
Time-out of [OFF] signal of Linear measure sensor
-----
604403 Teaching Height of Stocker Master
Error in DD-axis
-----
604404 Teaching Height of Stocker Master
Error in NS-axis
-----
604405 Teaching Height of Stocker Master
Error in DD/NS-axis
-----
604406 Teaching Height of Stocker Master
Time-out of DD/NS-axis
-----
604407 Teaching Height of Stocker Master
Error in calculating drive wave of HL-axis
-----
1012-005