4OM-1625-004_w.pdf - 第279页
4OM-1603 3-124 3. Error IDs and Remedial Procedures : Chap.3 1012-005 Error ID Error Name, Description, Cause, and Remedy 60041 1 Head Rotate center offset teach Error while L-axis is on zeroing ----- 600412 Head Rotate …

4OM-1603
3-123
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
600402 Head Rotate center offset teach
Error of Recognition Command response.
-----
600403 Head Rotate center offset teach
Error of coordinates calculation.
-----
600404 Head Rotate center offset teach
Error when Jig pickup began
-----
600405 Head Rotate center offset teach
Error in the movement of Jig pickup
-----
600406 Head Rotate center offset teach
Error when Jig store began
-----
600407 Head Rotate center offset teach
Error in the movement of Jig store
-----
600408 Head Rotate center offset teach
Error when HL-axis and NL-axis began zeroing.
-----
600409 Head Rotate center offset teach
Error while HL-axis and NL-axis are on zeroing
-----
60040a Head Rotate center offset teach
Error when DD-axis began to rotate
-----
60040b Head Rotate center offset teach
Error while DD-axis is rotating
-----
60040c Head Rotate center offset teach
Error of Data set for XY Beam.
-----
60040d Head Rotate center offset teach
Error of moving for XY Beam.
-----
60040e Head Rotate center offset teach
Time-out in XY Beam
-----
60040f Head Rotate center offset teach
Time-out of communication with recognition
-----
600410 Head Rotate center offset teach
Error when L-axis began zeroing
-----

4OM-1603
3-124
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
600411 Head Rotate center offset teach
Error while L-axis is on zeroing
-----
600412 Head Rotate center offset teach
Error when Z-axis began to rotate
-----
600413 Head Rotate center offset teach
Error while Z-axis is rotating
-----
600414 Head Rotate center offset teach
Error when L-axis began to drop
-----
600415 Head Rotate center offset teach
Error when L-axis is dropping
-----
600416 Head Rotate center offset teach
-----
-----
600501 Reference mark position teach
Could not recognize Glass Jig in CTR Fly Recognition.
Please check that Glass Jig is right on Glass Jig place(Check it because there is
a possibility that no nozzle is on head, or vacuum is not "ON")
600502 Reference mark position teach
Error of Recognition Command response in case of CTR Fly Recognition
-----
600503 Reference mark position teach
Could not recognize Standard Mark
-----
600504 Reference mark position teach
Error of Recognition Command response in case of Standard Mark Recognition
-----
600505 Reference mark position teach
Error of coordinates calculation of CTR Fly Recognition
-----
600506 Reference mark position teach
Error when Jig pickup of CTR Fly Recognition began
-----
600507 Reference mark position teach
Error of the movement of Jig pickup of CTP Fly Recognition
-----
600508 Reference mark position teach
Error when Jig store of CTR Fly Recognition began
-----
600509 Reference mark position teach
Error of the movement of Jig store of CTR Fly Recognition
-----

4OM-1603
3-125
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
60050a Reference mark position teach
Error when HL-axis, NL-axis of CTR Fly Recognition began zeroing.
-----
60050b Reference mark position teach
Error while HL-axis, NL-axis of CTR Fly Recognition is zeroing.
-----
60050c Reference mark position teach
Error when DD-axis of CTR Fly Recognition began to rotate.
-----
60050d Reference mark position teach
Error while DD-axis of CTR Fly Recognition is rotating.
-----
60050e Reference mark position teach
Error of Data set for XY Beam of CTR Fly Recognition
-----
60050f Reference mark position teach
Error of moving for XY Beam.
-----
600510 Reference mark position teach
Time-out in XY Beam movement
-----
600511 Reference mark position teach
Time-out in communication with Recognition
-----
600512 Reference mark position teach
Error of coordinates calculation of Standard Mark Recognition
-----
600513 Reference mark position teach
Error of moving for XY Beam.
-----
600514 Reference mark position teach
Time-out in XY Beam movement
-----
600515 Reference mark position teach
Time out in communication with Recognition
-----
600601 Nozzle position offset teach
Could not recognize nozzle
Is Nozzle placed? Is right Nozzle position data set? Please check them.
600602 Nozzle position offset teach
Error of Recognition Command response.
-----
600603 Nozzle position offset teach
Error of coordinates calculation.
-----