4OM-1625-004_w.pdf - 第257页
4OM-1603 3-102 3. Error IDs and Remedial Procedures : Chap.3 1012-005 Error ID Error Name, Description, Cause, and Remedy 4b0e01 Splicing tape set error The joint part of splicing tape is not correctly set. Please extrac…

4OM-1603
3-101
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
LightEmitterandReceivercouldhave
awandsoil.Pleasecleanitup.Please
press [Operation] on the screen(Unit adjustment -> Linear measure Sensor ->
DetectiontestScreen)andconrmwhether
thereisanerror
4b0804 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken
4b0805 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken. Either, Please update Version
on the screen(Unit adjustment -> Linear measure Sensor -> Correct data read
Screen)
4b0807 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
PleaseconrmErrorfromLogRequest
Screen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0808 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
PleaseconrmErrorfromLogRequest
Screen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0809 Linear measure operation error
There is a problem in the linear measure Sensor.(Strobe Signal did not turn off
within predetermined time.)
PleaseconrmErrorfromLogRequest
Screen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0c01 NozzleConrmationErrorbeforepickup
compDetectAfterPlacement)
Because a component was found on a nozzle, it stopped after disposal.
The result could have some problems.
Please check placement state on placement step recovery screen.
4b0c02 NozzleConrmationErrorbeforepickup
comp
The remains component was found on a nozzle during production.
PleaseconrmwhetherthereisanerrorintheP.C.B.
4b0c03 NozzleConrmationErrorbeforepickup
compDetectAfterDiscard
Because a component was found on a nozzle, it stopped after disposal.
Pleaseconrmandcleanupthenozzleifthiserrorcontinues.

4OM-1603
3-102
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Opensafetycoverandconrmthe
componentonP.C.B.Pleaseremoveitor
revise it
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b200c P.C.B Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.

4OM-1603
3-103
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
4b200d P.C.B Height Measurement
Recovery by the multipoint measurement failed because the measurement result
wasinsufcient.
Check the measurement position.
4b2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P
.C.B Height Measurement
Measurement time-out
-----
4b2084 P.C.B Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please
conrmthecableofSSC
network.
4b2102 SSC network abnormal
Thereisaprobleminconnection
toServoAmplier(XY).
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)Checkwhetherornottheservoampliersaredamaged.
4b2103 SSC network abnormal
Thereisaprobleminconnection
toServoAmplier(Head).
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)Checkwhetherornottheservoampliersaredamaged.
4b2301 Feeder (Servo Error)
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control P.C.B.)
Please replace the feeder. (Do not disconnect the feeder in powering on,
otherwise it may cause the inside data broken.)
4b2302 Feeder (Servo Error)
Alarm Code:A1 - Over Current Error (Foreign substances in the tape feeding drive
section)
Conrmwhetherornotthetape
isbeingjammedonthepath./Conrmthereelto
operatesmoothly./Conrmwhetherornotsomecomponentsanddustarebeing
caughtinthesprocket./Conrmwhetherornotsomecomponentsanddustare
being caught in the tape feeding gear.
4b2303 Feeder (Servo Error)
Alarm Code:A2 - Others
-----