4OM-1603 1-33 3. Maintenance Spots : Chap.1 Notice Head U/D Ball Screw (HL Axis) (1) W ipe off the old grease with a rag and apply a small amount of new grease to the groove of the ball screw with a syringe (2) After lub…

100%1 / 347
4OM-1603
1-32
3. Maintenance Spots : Chap.1
3.2.7 Head Section
High-Speed Head
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
When any fat or oil is stuck to the line sensor,
rub off the dirt using a cotton applicator dipped
in dehydrated ethanol.
Nozzle U/D Ball Screw (NL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Use No. 19 (brown) nozzle.
Note
No. 19
Wipe off the old grease with a rag and apply a
small amount of new grease to the groove of
the ball screw with a syringe.
Notice
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
(1) Store all nozzles in the nozzle stocker
(housing) through window navigations.
(2)
Sebum or oil should not
adhere to the surface of the
diffusion plate.
Refer to "5. Nozzle Change
Window" in "Chapter 6 (Vol. 2)"
for the procedure of nozzle storage.
Reference
Wipe the diffusion plate with a dry lens
cleaning cloth.
F4A25
1012-004
4OM-1603
1-33
3. Maintenance Spots : Chap.1
Notice
Head U/D Ball Screw (HL Axis)
(1) Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe
(2) After lubrication, move the HL-axis up
and down 25 mm five times using the
manual axis operation to smooth the grease.
No.19
(3) Grease should be applied every 3 months
after the initial month.
Apply grease, taking care that
the grease does not stick to the
sensor.
No.19
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Use No. 19 (brown) nozzle.
Note
Head U/D Linear Guide (HL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe
(2) After lubrication, move the HL-axis up
and down 25 mm five times using the
manual axis operation to smooth the grease.
Use No. 19 (brown) nozzle.
Note
F4A25-1
1012-004
4OM-1603
1-34
3. Maintenance Spots : Chap.1
1012-005
Cam Followers
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
If foreign substances adhere to the cam
followers, remove them with a pair of tweezers.
Apply grease (0.01 cc) to the upper sides
of the cam followers with a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
No. 19
Center Spline
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 4 minutes
Apply grease to the groove of the center spline
with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Nozzle Change Cam Face (Upper Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
If a foreign substance adheres to the cam face,
remove it with a pair of tweezers.
Apply grease (0.01 cc) to the upper side of
the cam face with a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
Note
No. 19
Vacuum Filters (15 locations)
Every 3 Months Replacement
Required Time: 30 minutes
Pull up the 2 vacuum filters with the filter
attachment/detachment jig and replace it with
a new one.
Use commercially available tweezers
for filter changes.
F4A26