4OM-1603 2-24 3. Machine Information : Chap.2 1012-005 Machine Information Code Display Area A (The outline of the Machine Information) Display Area B (The details of the Machine Information) 801 101 Nozzlediametercon…

4OM-1603
2-23
3. Machine Information : Chap.2
Machine
Information Code
Display Area A (The outline of the Machine Information)
Display Area B (The details of the Machine Information)
80060a Alternated Feeder
Feeder unloading
-----
800801 Start Auto Recovery Mode
Shortage of component
-----
800802 Start Auto Recovery Mode
Splice waiting
-----
800803 Start Auto Recovery Mode
Comp. Vertical(sensor)
-----
800804 Start Auto Recovery Mode
Comp. Thickness(sensor)
-----
800805 Start Auto Recovery Mode
Comp. Missing(sensor)
-----
800806 Start Auto Recovery Mode
Comp. Recog. Error(recog.)
-----
800807 Start Auto Recovery Mode
Comp. Missing(recog.)
-----
800808 Start Auto Recovery Mode
Coplanarity Check Error
-----
800809 Start Auto Recovery Mode
Feeder Alarm
-----
80080a Start Auto Recovery Mode
Feeder unloading
-----
80080b Start Auto Recovery Mode
Device Op is stopped because Feeder is not loaded.
-----
80080c Start Auto Recovery Mode
Etc
-----
800902 Alarm for Shortage of Comp.
Few components to feed.
-----
1012-005

4OM-1603
2-24
3. Machine Information : Chap.2
1012-005
Machine
Information Code
Display Area A (The outline of the Machine Information)
Display Area B (The details of the Machine Information)
801101 Nozzlediameterconrmation
The disagreement of the nozzle diameter was detected with the linear measure.
Thereisapossibility
ofthelinearmeasuredirtandthenozzledirt,pleaseconrm
whether a different nozzle has adhered.
-----
801b01 Lightning Surge alarm
Lightning Surge Protector works; Q204.
-----
801b02 Lightning Surge alarm
Lightning Surge Protector works; Q204. Running continue.
-----
801b03 Lightning Surge alarm
Protective Fuse error of lightning Surge Protector. Exchange the fuse.
-----
801c05 Information
Warm start mode was canceled.
-----
801c06 Information
The machine stopped by the automatic stop function.
-----
802001 Alarm for Splicing
The feeder is running short of the component to feed.
Please prepare for Splicing, and remove the cover tape from the storage section.
-----
802101 Feeder Maintenance alarm
The total number of feeder's shots reached a previous notice setting number.
-----
802102 Feeder Maintenance alarm
The feeder adsorption rate decreased and exceeded the previous notice setting
number.
-----
802201 ACV Information
ACV
CheckError.ComponentID
onthefeederisnotsameasonespeciedby
current program.
-----
802202 ACV Information
Device(Rear) Cannot clear Clamp for feeder communication. Please operate it
again later.
-----
802203 ACV Information
Device(Front) Cannot clear Clamp for feeder communication.
Please operate it again later.
-----

4OM-1603
2-25
3. Machine Information : Chap.2
Machine
Information Code
Display Area A (The outline of the Machine Information)
Display Area B (The details of the Machine Information)
802204 ACV Information
Device(Rear) Cannot clear Clamp for receiving the result of ACV Check Error.
Please operate it again later.
-----
802205 ACV Information
Device(Front) Cannot clear Clamp for receiving the result of ACV Check Error.
Please operate it again later.
-----
802206 ACV Information
Device(Rear) Time-out for receiving the result of ACV Check Error.
Please take out Feeder and then take it in again.
-----
802207 ACV Information
Device(Front) Time-out for receiving the result of ACV Check Error.
Please take out Feeder and then take it in again.
-----
802208 ACV Information
Device(Rear) Time-out of Feeder communication.
Please take out Feeder and then take it in again.
-----
802209 ACV Information
Device(Front) Time-out of Feeder communication.
Please take out Feeder and then take it in again.
-----
802301 Splicing No Check Alarm
The seam passed the detection sensor as unregistered splicing.
Please register the splicing.
-----
802401 Feeder
CoverTapelledupalarm
The
storagesectionofCoverTapelledwasdetected.
Please remove Tape from internal storage section.
-----
802501 Feeder Communication Error
Failed to displaying Operational Panel.
Please put the Cart down, or pull out and insert Feeder.
-----
802502 Feeder Communication Error
The communication processing of Feeder was not done in prescribed time.
-----
802601 Linear measure sensor
To set synchronized counting position of Head(Rear) is failed.
-----
802602 Linear measure sensor
To set synchronized counting position of Head(Front) is failed.
-----