4OM-1625-004_w.pdf - 第236页
4OM-1603 3-81 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 49077D Nozzle set up RecognizingNozStockerMarkhasnot nishedwithinpredeterminedtime. ----- 49077E N…

4OM-1603
3-80
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
49076F Nozzle set up
Error in turning on PCB recog camera Light
-----
490770 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490771 Nozzle set up
TurningonPCBrecogcamera
Lighthasnotnishedwithinpredeterminedtime
(Teaching Noz Stocker)
-----
490772 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490773 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490774 Nozzle set up
TurningonPCBrecogcamera
Lighthasnotnishedwithinpredeterminedtime
(Noz Recog)
-----
490775 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490776 Nozzle set up
Error in turning off PCB recog camera Light
-----
490777 Nozzle set up
TurningoffPCBrecogcamera
Lighthasnotnishedwithinpredeterminedtime
-----
490778 Nozzle set up
Error in turning off PCB recog camera Light
-----
490779 Nozzle set up
Error in capturing a image of PCB recog camera.
-----
49077A Nozzle set up
CapturingaimageofPCBrecog
camerahasnotnishedwithinpredetermined
time
-----
49077B Nozzle set up
Error in capturing a image of PCB recog camera.
-----
49077C Nozzle set up
Error in recognizing Noz Stocker Mark
-----

4OM-1603
3-81
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49077D Nozzle set up
RecognizingNozStockerMarkhasnot
nishedwithinpredeterminedtime.
-----
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
RecognizationoftheexistenceofNoz
hasnotnishedwithinpredeterminedtime
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
RecognizingNozIDhasnotnished
withinpredeterminedtime
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting linear Measure detect
-----
490786 Nozzle set up
Time-out of reading out the result of Linear Measure detect
-----
490787 Nozzle set up
Error in the result of Linear Measure detect
-----
490788 Nozzle set up
Time-out of starting linear Measure detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Linear Measure detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Linear Measure detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
1012-005

4OM-1603
3-82
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
49078D Nozzle set up
ExchangingNozhasnotnishedwithin
predeterminedtime
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
490801 Program -change linked operation
Program-change
linkedoperationhasnotnished
withinappointedtime.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
PleaseremovetheBackupPin\Jigfrom
BackupBase.Or,conrmwhether
Sensor has error or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
ConrmresetMethodofdetailedSub-system
errorcountsofAlarm.
1012-005