4OM-1625-004_w.pdf - 第287页
4OM-1603 3-132 3. Error IDs and Remedial Procedures : Chap.3 1012-005 Error ID Error Name, Description, Cause, and Remedy 601a0d Linear measure sensor correction re-teach The measurement value of the nozzle is not within…

4OM-1603
3-131
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
601a01 Linear measure sensor correction re-teach
The linear measure reading is abnormal.
Pleaseconrmwhetherthenozzlehas
adheredtotheposition.
601a02 Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure sensor correction re-teach
Nozzle can not be detected.
-----
601a04 Linear measure sensor correction re-teach
Line Sensor Control is abnormal.
-----
601a05 Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/R-Err7)
-----
601a06 Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/NR-Err8)
Offset correction can not be completed. Please use the big nozzle(HA05) teach
-----
601a07 Linear measure sensor correction re-teach
again and adjust the light & receive optical Axis(Edge detect error-Err9)
-----
601a08 Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again
andadjustthelight&
receiveopticalAxis(Insufcientsamples-Err10)
-----
601a09 Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
againandadjustthelight&
receiveopticalAxis(Insufcientcorrectingsamples-
Err14)
-----
601a0a Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Fail to create correction-Err15)
-----
601a0b Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Accuracy check NG-Err16)
-----
601a0c Linear measure sensor correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Fail to save-Err17)
-----

4OM-1603
3-132
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
601a0d Linear measure sensor correction re-teach
The measurement value of the nozzle is not within 0.2mm to 0.6mm.
Adjust the height of the linear measure sensor otherwise, replace it.
601a0e Linear measure sensor correction re-teach
The linear measure control has an error.(err2, err3)
All E/NR Error. There is a possibility that Light Emitter or Receiver is broken.
601a0f Linear measure sensor correction re-teach
The linear measure control has an error.(err1)
Could be P.C.B. Error
601a10 Linear measure sensor correction re-teach
The linear measure control has an error.(err4)
A quantity of light emitter is dropping. There is a possibility of Light Emitter broken.
601a11 Linear measure sensor correction re-teach
No strobe response
Please
conrmthewiringofHLS.
Either,conrmP.C.B.address.
601f01 NL Axis offset teach
Error before Line Sensor measurement began
-----
601f02 NL Axis offset teach
ODD Noz is placed on Head, or error is detected during linear measure sensor.
-----
601f03 NL Axis offset teach
Error of NS-axis movement
-----
601f04 NL Axis offset teach
Error of DD-axis movement
-----
601f05 NL Axis offset teach
Error of NL-axis movement
-----
601f06 NL Axis offset teach
Error of DD/NS-axis movement
-----
601f07 NL Axis offset teach
Time-out when Line Sensor measurement began
-----
601f08 NL Axis offset teach
Read Time-out of Line Sensor measurement
-----
601f09 NL Axis offset teach
Time-out of NL-axis movement
-----
601f0a NL Axis offset teach
Time-out of DD/NS-axis movement
-----

4OM-1603
3-133
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
601f0b NL Axis offset teach
Error during Teach
-----
602001 Writing Line measure Sensor Program
Fail to write Line Sensor Program
-----
602101 Teaching Tray Pallet Transition
Elevator Check Error
-----
602102 Teaching Tray Pallet Transition
Error in Elevator axis movement position calculating
-----
602103 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602104 Teaching Tray Pallet Transition
Time-out in elevator axis movement
-----
602105 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602106 Teaching Tray Pallet Transition
Time-out in elevator axis movement
-----
602107 Teaching Tray Pallet Transition
Elevator axis Movement Error
-----
602108 Teaching Tray Pallet Transition
Error in elevator Stop Auto Run
-----
602109 Teaching Tray Pallet Transition
Time-out in elevator Stop Auto Run
-----
60210A Teaching Tray Pallet Transition
-----
-----
60210B Teaching Tray Pallet Transition
Program Error
-----
602201 Teaching Pulling Traverse
Pre-check error in driver-axis
-----
602202 Teaching Pulling Traverse
Elevator is not in Component Reload position
-----
1012-005