4OM-1625-004_w.pdf - 第200页
4OM-1603 3-45 3. Error IDs and Remedial Procedures : Chap.3 1012-005 Error ID Error Name, Description, Cause, and Remedy 427108 Detection of Output conveyor sensor P .C.B. on stop sensor was not detected after movement c…

4OM-1603
3-44
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
426201 positioning conveyor timeout
Placement for input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input conveyor to Input
positionorisdropped.Pleaseconrm
fromInputtopositioningconveyor.
426202 positioning conveyor timeout
Output from input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.Pleaseconrmfrompositioningto
Outputconveyor.
426203 positioning conveyor timeout
Placement for output position was not completed within predetermined time.
P.C.B. inserted is place in Output position. There is a possibility of it fallen. Please
conrmfromInputtoPositioningconveyor
.
426204 positioning conveyor timeout
Output from output position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.Pleaseconrmfrompositioningto
Outputconveyor.
426301 positioning conveyor Error
Error in positioning conveyor
-----
427101 Detection of Output conveyor sensor
Decrease sensor was detected before starting.
ThereisanindeniteP.C.B.
onOutputconveyor.Pleaseremoveit.
427102 Detection of Output conveyor sensor
Decrease sensor was not detected before starting the movement
P.C.B. to output is not found
1. Please put P.C.B. on Sensor.
2. Thereisapossibility
ofP.C.B.fallen.Conrmtheconveyorwidth.
427103 Detection of Output conveyor sensor
Stop sensor was detected before starting.
ThereisanindeniteP.C.B..
Pleaseremoveit.
427104 Detection of Output conveyor sensor
Stop sensor was not detected before starting.
CannotndP.C.B.tooutput.
1. Is P
.C.B. detected by sensor?
2. There is a possibility that P.C.B. is falling. Please check the width of conveyor.
427105 Detection of Output conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
ThereisanindeniteP.C.B.
onOutputconveyor.Pleaseremoveit.
427106 Detection of Output conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thaveError.
427107 Detection of Output conveyor sensor
P.C.B. on stop sensor was detected after movement completion
Thereis
anindeniteP.C.B.
onOutputconveyor.Pleaseremoveit.

4OM-1603
3-45
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
427108 Detection of Output conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’thaveError.
427109 Detection of Output conveyor sensor
P.C.B. on output conveyor was detected
Please remove P.C.B. from the conveyor
42710a Detection of Output conveyor sensor
P.C.B. on output conveyor was not detected
Please check whether P
.C.B. is detected correctly.
Checkwhetherthesensordoesn’thave
Error.
42710b Detection of Output conveyor sensor
Stop sensor is not passed during Output operation
The conveyor is stopped before P.C.B. goes through Sensor.
1. Conrmoutputmethod,transitionspeed,
timersetting.
2. Check the connected cable.
42710c Detection of Output conveyor sensor
Disengaged P.C.B. of output conveyor
P.C.B. was removed from Output Conveyor.
Please check the state of it if removing P.C.B. does not happen intentionally.
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the above conveyor.
427202 Output conveyor timeout
Output was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the transition with Output Machine.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 Middle Conveyor Error
Time-out in Placement from Input Machine.
PCB is not placed in Device. Please check Middle Conveyor.
1.
Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 Middle Conveyor Error
Time-out in Output for Output Machine.
PCB is not outputted from Device. Please check Middle conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3.
Whether Breaker is falling down

4OM-1603
3-46
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
428001 Error in the communication of P.C.B. transfer
Input Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of Input Machine.
2. Check the connected cable.
428002 Error in the communication of P.C.B. transfer
Output Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of output Machine.
2. Check the connected cable.
428101 Line PCB transfer error
T
ime-out of Placement
Line PCB transfer was not completed in prescribed time.
1. There is a possibility that PCB is caught. Please Check the Conveyor.
2. Pleaseconrm
whetherConnect
cableisnormallyconnectedornot.
428201 Transfer Error between Devices
Time-out of starting Input Machine
Could not start Output from Input Machine. Error in Input Machine.
428202 Transfer Error between Devices
Time-out of starting Output Machine
Could not receiver Start Signal from Output Machine. Error in output Machine.
428203 Transfer Error between Devices
Output Machine Error
Error during placement of Output Machine. Transfer will be stopped.
429001 Manual transfer Error
Time-out in Conveyor
The Conveyor didn't stop within predetermined time.
Please
conrmthestateoftransfer
driver.
42a001 Shuttle Conveyor Communication Error
Failed in getting Shuttle Conveyor Control Information.
Communication Error between CPU1 and CPU2 has occurred.
Please restart Machine.
42a101 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a102 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please put PCB on Sensor.
2. There is a possibility that PCB drops. Please check out Conveyor width.
42a103 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
1012-005