EN 3.pdf - 第17页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.2 BOARD V ersion 01 Tit le Sign of board malfunctions Page 3-2-4 Note Classification Head AMP Board Axis IO Board SBC Board NT A8 Board Back Plane Board V ision IF Boar…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.2 BOARD
Version
01
Title
Sign of board malfunctions
Page
3-2-3
Note
Classification
Head
AMP
Board
Axis
IO
Board
SBC
Board
NT
A8
Board
Back
Plane
Board
Vision
IF
Board
Feeder
IO
Board
CAN
Conveyor
Board
Conveyor width
adjustment errors.
O
Front/Rear Control
Panel, Teaching Box
do not
operate.(Button
LED off.)
O O
Front/rear keyboard
or mouse do not
operate.(USB can't
be used.)
O
Tower Lamp
defects.(buzzer
sound not heard.)
O
Error or alarm
occurs when the
head picks up the
ANC nozzle or
places it in the
ANC.
O O
Feeder operation
failure, and feeder
base slot operation
error.
O
"Feeder Unlock
detected" error
occurs.
O
"ANC Shutter can't
be closed or
opened" error
occurs.
O
When the
equipment is turned
on, the feeder is fed
first.
O
"Feeder Part Clamp
is released" error
occurs.
O
Head Ball spline
damages, bending
or shaking.
O O

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.2 BOARD
Version
01
Title
Sign of board malfunctions
Page
3-2-4
Note
Classification
Head
AMP
Board
Axis
IO
Board
SBC
Board
NT
A8
Board
Back
Plane
Board
Vision
IF
Board
Feeder
IO
Board
CAN
Conveyor
Board
Head Z,R axis
noises, vibration,
shaking, and so on.
O O
"Alarm detected on
head axis" error
occurs.
O O
Homing error on a
head axis.
O O
"Alarm detected on
head axis" error
occurs.
O O
Head Homing not
allowed.
O O
Head's axial motor
or homing location
is changed” error
occurs.
O O
No signal on the
monitor during
power on.
O O
Blue screen during
booting or
operation.
O O
While loading the
MMI
"Grabber type does
not match…" "fail
to run visframe"
"Run Time Error"
error
O
MMI or PC down
during MMI
operation.
O O
PC booting repeats. O O
MMI downloading
stopped.
O O

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.2 BOARD
Version
01
Title
Sign of board malfunctions
Page
3-2-5
Note
Classification
Head
AMP
Board
Axis
IO
Board
SBC
Board
NT
A8
Board
Back
Plane
Board
Vision
IF
Board
Feeder
IO
Board
CAN
Conveyor
Board
Cannot boot due to
HDD detection
error.
O
PC processing speed
slow and freezing
up.
O O
While loading the
MMI
Initializing
Machine I/F...
errors.
O O O O
"Assert Fail" errors. O
Monitor video off
(intermittent)
decolorization,
screen shaking.
O
MFC related
arithmetic error
when booting the
MMI. (Not Found
System)
O
Pick up error O O O
Failed to detect a
part.
O
Gantry Mounting
Offset off.
O
Optimizer execution
paused.
O
Forcefully
terminating the
MMI after running
the Optimizer.
O
PCB File
Downloading fails.
O