EN 3.pdf - 第334页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.19 ELECTRIC DEVICE V ersion 01 Tit le MAIN POWER SHORT TEST Page 3-19-8 Note 6. Measure the insulation resistance between TB#1 and the Earth Plate. Inspection units Ins…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
MAIN POWER SHORT TEST
Page
3-19-7
Note
Inspection units Inspection criteria
MC#1 의 SHORT CHECK : MC1-2 , MC 1-4
100MΩ or higher or OPEN
MC#1 의 SHORT CHECK : MC1-2 , MC 1-6
20kΩ ~ 40kΩ
*Condition : CP#1 OFF, CP#2 OFF, CP#3 OFF
4. Measure the TB#1's 110V, 220V(1ø,3ø) insulation resistance.
Inspection units Inspection criteria
T/B1 AC power 의 SHORT CHECK : 1L1 , 1L2
10kΩ ~ 15kΩ
T/B1 AC power 의 SHORT CHECK : 22R , 22T
3MΩ ~ 5MΩ
T/B1 AC power 의 SHORT CHECK : 22L1 , 22L3
20kΩ ~ 40kΩ
T/B1 AC power 의 SHORT CHECK : 22L2 , 22L3
100MΩ or higher or OPEN
T/B1 DC power 의 SHORT CHECK : 11A/B(24V
B) ,12A/B(24G)
T/B1 DC power 의 SHORT CHECK : 11C/D(24V)
,12C/D (24G)
*Condition : CP#1 OFF, CP#2 OFF, CP#3 OFF
5. Measure the insulation resistance of Relay#1,11.
Inspection units Inspection criteria
RY#1 의 SHORT CHECK : RY1-7, 8
10kΩ ~ 15kΩ
RY#11 의 SHORT CHECK : RY11-13, 14
200Ω ~ 350Ω
*Condition : CP#1 OFF, CP#2 OFF, CP#3 OFF

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
MAIN POWER SHORT TEST
Page
3-19-8
Note
6. Measure the insulation resistance between TB#1 and the Earth Plate.
Inspection units Inspection criteria
EARTH PLATE 의 SHORT CHECK : F.G , 1L1
100MΩ or higher or OPEN
EARTH PLATE 의 SHORT CHECK : F.G , 1L2
EARTH PLATE 의 SHORT CHECK : F.G , 22R
EARTH PLATE 의 SHORT CHECK : F.G , 22T
EARTH PLATE 의 SHORT CHECK : F.G , 22L1
EARTH PLATE 의 SHORT CHECK : F.G , 22L2
EARTH PLATE 의 SHORT CHECK : F.G , 22L3
*Condition : Short check between the earth terminal and the AC power.
7. Noise Filter resistance measurement
Inspection units Inspection criteria
NF#1 의 SHORT CHECK : NF1-R , NF1-S
600 ~ 750 kΩ
NF#1 의 SHORT CHECK : NF1-R , NF1-T
600 ~ 750 kΩ
NF#1 의 SHORT CHECK : NF1-S , NF1-T
600 ~ 750 kΩ
*Condition : MCCB ON, Main Power S/W OFF
Inspection units Inspection criteria
NF#1 의 SHORT CHECK : NF1-R , NF1-S
3Ω or less
NF#1 의 SHORT CHECK : NF1-R , NF1-T
3Ω or less
NF#1 의 SHORT CHECK : NF1-S , NF1-T
3Ω or less
*Condition : MCCB ON, Main Power S/W ON

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
MAIN POWER SHORT TEST
Page
3-19-9
Note
8. Measure the insulation resistance/power at the AC 220V input and the DC 24V output.
Measure the insulation resistance at the AC220V input.
Inspection units Inspection criteria
PS#1 AC input : L, N 900 ~ 1050KΩ
PS#2 AC input : L, N 900 ~ 1050KΩ
PS#3 AC input : L, N 900 ~ 1050KΩ
PS#4 AC input : L, N 900 ~ 1050KΩ
PS#5 AC input : L, N 900 ~ 1050KΩ
PS#6 AC input : L, N 900 ~ 1050KΩ
DC24V output's insulation resistance
Inspection units Inspection criteria
PS#1 DC output : +, - 900 ~ 1050KΩ
PS#2 DC output : +, - 900 ~ 1050KΩ
PS#3 DC output : +, - 900 ~ 1050KΩ
PS#4 DC output : +, - 900 ~ 1050KΩ
PS#5 DC output : +, - 900 ~ 1050KΩ
PS#6 DC output : +, - 900 ~ 1050KΩ
AC220V input power
Inspection units Inspection criteria
PS#1 AC input : L, N AC 220V±10
PS#2 AC input : L, N AC 220V±10
PS#3 AC input : L, N AC 220V±10
PS#4 AC input : L, N AC 220V±10
PS#5 AC input : L, N AC 220V±10
PS#6 AC input : L, N AC 220V±10
DC24V output power
Inspection units Inspection criteria
PS#1 DC output : +, - DC 24V±0.72
PS#2 DC output : +, - DC 24V±0.72
PS#3 DC output : +, - DC 24V±0.72
PS#4 DC output : +, - DC 24V±0.72
PS#5 DC output : +, - DC 24V±0.72
PS#6 DC output : +, - DC 24V±0.72