EN 3.pdf - 第186页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.1 1 HEAD V ersion 01 Tit le HEAD CABLE WIRING Page 3-1 1-26 Note Connect the Head IO Board Cable. Connect the Head Connector .

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.11 HEAD
Version
01
Title
HEAD CABLE WIRING
Page
3-11-25
Note
Place the tube so that it does not interfere with other modules.
Connect the control cable.
Connect the Motor IF Board Cable.
Check the Cable Label and connect it to the Board.
Fixing order : CN15, CN14, CN13, CN12, CN11, CN20, CN19, CN18, CN17, CN16 ,CN21, CN22
Fix the cable with a tie and ground it.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.11 HEAD
Version
01
Title
HEAD CABLE WIRING
Page
3-11-26
Note
Connect the Head IO Board Cable.
Connect the Head Connector.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.11 HEAD
Version
01
Title
Z AXIS NOISE DECISION CRITERIA
Page
3-11-27
Note
[Z AXIS NOISE DECISION CRITERIA]
1. Check the noise level in Hz, Gain dB.
2. Check the ID (1st Notch Frequency) Setting Valve.
3. If the ID (1st Notch Frequency) Setting Valve is not matched, change the ID from 500Hz → 700Hz.
4. After changing the ID value, check if the magnitude is changed. (Hz changed to less than 0 dB.)
5. If the noise is removed but there is a little vibration, then change the 1E (1st Notch Width Selection) value
from 1 → 2 → 3.
*Parameter adjustment range
Part No. Basic Range
1D 500Hz 500~650Hz
1E 1 1~2
28 310Hz 280~380Hz
29 1 1~2
2A 30 30~50