Model DECAN Series Company SAMSUNG TECHWIN Module 3.18 V ACUUM DEVICE V ersion 01 Tit le REAR SOL ASSY SUB ASSEMBL Y Page 3-18-8 Note  Sol V alve Assy 1,2 Air Pressure T ube Connection Diagram  Sol V alve Assy 1,2 Asse…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
REAR SOL ASSY SUB ASSEMBLY
Page
3-18-7
Note
[REAR SOL ASSY SUB ASSEMBLY]
Sol Valve Assy 1 Assembly
The Silencer or Plug requires Teflon tape to be attached to it. Fix it after attaching tape.
When assembling the fitting, pay attention to the direction of assembly.
Sol Valve Assy 2 Assembly
The Silencer or Plug requires Teflon tape to be attached to it. Fix it after attaching tape.
When assembling the fitting, pay attention to the direction of assembly.
Sol Valve Assy 1,2 Air Pressure Diagram
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
REAR SOL ASSY SUB ASSEMBLY
Page
3-18-8
Note
Sol Valve Assy 1,2 Air Pressure Tube Connection Diagram
Sol Valve Assy 1,2 Assembly into the Base Frame
Assemble it into the Cover Frame in the bottom rear right of equipment.
When assemble it, make sure that the cable and the operation switch face out.
Sol Valve Assy Air Tube Path
Right : 6 Yellow 1700mm, 6 Black 1700mm, 4 Black 1700mm
Left : 6 Yellow 3200mm, 6 Black 3200mm, 4 Black 3200mm
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
VACUUM PUMP & AIR PRESSURE CHECK
Page
3-18-9
Note
[VACUUM PUMP & AIR PRESSURE CHECK]
Run a Running Test to check everything.(Error Log File check)
Separate the cover from the front bottom of the equipment and check the type of vacuum pump.
Pump Type Generator(Ejector) Type
See if the Vacuum Pressure sticker attached to the front is same as the Vacuum Pump Type.
Pump Type Generator(Ejector) Type
In the MMI, select <Diagnosis> → <F5(Vacuum)> and check the Vacuum Level / Blow level.
Inspection criteria
Vacuum Level "0" point check : Current Level value -9 ~ 9 mmHg or less.
When the Nozzle is not mounted, check the vacuum level for each head: For each head, 60 ~ 120 mmHg.
When the CN040 Nozzle is mounted, check the vacuum level: For each head, 480 mmHg or greater.
When the Nozzle is blocked, 600mmHg or greater.
When the CN040 Nozzle is mounted, check the amount of blow : -90 ~ -70 mmHg.
Repeat the Sol Valve Check 30 times and see if the Red Lamp is lit.