EN 3.pdf - 第287页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.16 X-FRAME V ersion 01 Tit le X AXIS NOISE DECISI ON CRITERIA Page 3-16-6 Note [X AXIS NOISE DECISION CRITERIA] 1. Reduce the Parameter's No.28(2nd Notch Frequency…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
GREASE INJECTION
Page
3-16-5
Note
[GREASE INJECTION]
Inject grease into the two places marked.
Check if the tube is bent or it is well fit into the fitting. Use a grease injector to inject grease into five
places.
Inject until the grease reaches the fitting.
While pushing the frame back and forth, see if the LM Guide or Ball Screw has grease st ains on it.
If not, inject grease.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
X AXIS NOISE DECISION CRITERIA
Page
3-16-6
Note
[X AXIS NOISE DECISION CRITERIA]
1. Reduce the Parameter's No.28(2nd Notch Frequency) by 10HZ and see if there is noise.
2. If there is no noise, then reduce it down to 150Hz to check if noise or vibration is maintained.
3. If the noise is amplified, then increase the frequency by 10Hz to check for noises.
* See if the vibration continues until a max 190 ㎐.
4. After modifying No.28(2nd Notch Frequency), if there is slight noise or vibration, then increase the No.29
(2nd Notch Width Selection) by one Hz up to a max 3 and see if noise is heard.
5. If the noise is amplified, then reduce it by one to see if there is noise heard.
* Parameter adjustment range
Para No. Basic Range
28 130Hz 120~180Hz
29 1 1~3
2A 30 10~60
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
XY-DUCT X AXIS CABL E WIRING
Page
3-16-7
Note
[XY-DUCT X AXIS CABLE WIRING]
XY Duct's X axis Cable Wiring1
Push the Flat Cable to the opposite side and fix the belt.
XY Duct's X axis Cable Wiring2
Y Motor Unit Cable Wiring
As shown below, assemble the Y Motor Cable into the Connector of the Flat Cable from the bottom of the
Connector Bracket.