Model DECAN Series Company SAMSUNG TECHWIN Module 3.18 V ACUUM DEVICE V ersion 01 Tit le FRONT SOL ASSY SUB ASSEMBL Y Page 3-18-5 Note [FRONT SOL ASSY SUB AS SEMBL Y]  Sol V alve Assy 1 Assembly  The Silencer or Plug r…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
MAIN AIR & BLOW REGULATOR CHECK
Page
3-18-4
Note
[MAIN AIR & BLOW REGULATOR CHECK]
1. On the OP Panel, turn on the Ready Switch.
2. Turn the Air Regulator Adjustment Valve CW and CCW to 4.0 or below. Now, see if the Ready Switch on
the OP panel is turned off.(Air Pressure Sensor's OUT should be turned on: "1→2".)
3. Turn the Air Regulator Adjustment Valve CW to reach 4.5 and check if the Air Pressure Sensor Out is
turned on: "2→1".
4. Check if the Blow Air Regulator reading is 0.9~1.0 bar.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
FRONT SOL ASSY SUB ASSEMBLY
Page
3-18-5
Note
[FRONT SOL ASSY SUB ASSEMBLY]
Sol Valve Assy 1 Assembly
The Silencer or Plug requires Teflon tape to be attached to it. Fix it after attaching tape.
When assembling the fitting, pay attention to the direction of assembly.
Sol Valve Assy 2 Assembly
The Silencer or Plug requires Teflon tape to be attached to it. Fix it after attaching tape.
When assembling the fitting, pay attention to the direction of assembly.
Sol Valve Assy 1,2 Air Pressure Diagram
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
FRONT SOL ASSY SUB ASSEMBLY
Page
3-18-6
Note
Sol Valve Assy 1,2 Air Pressure Tube Connection Diagram
Sol Valve Assy 1,2 Assembly into the Base Frame
Assemble it into the Cover Frame in the bottom front left of equipment.
When assemble it, make sure that the cable and the operation switch face out.
Sol Valve Assy Air Tube Path
Left : 6 Yellow 1700mm, 6 Black 1700mm, 4 Black 1700mm