EN 3.pdf - 第346页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.19 ELECTRIC DEVICE V ersion 01 Tit le VOL T AGE CHECK TEST Page 3-19-20 Note  AC/DC power activated with Ready ON. 1. MC #1 power measurement Inspection units Inspecti…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-19
Note
Inspection units Inspection criteria
FRONT HEAD IF BD CN1 : CN1-B1, CN1-A1
DC 24V±0.72
FRONT HEAD IF BD CN1 : CN1-B2, CN1-A2
REAR HEAD IF BD CN1 : CN1-B1, CN1-A1
REAR HEAD IF BD CN1 : CN1-B2, CN1-A2
13. Front/Rear Z Axis Drive Power Cable voltage measurement
Inspection units Inspection criteria
FRONT Z axis DRIVE POWER CABLE : FZ12-CN5-1, FZ12-CN5-
2
DC 24V±0.72
FRONT Z axis DRIVE POWER CABLE : FZ910-CN5-1, FZ910-CN
5-2
REAR Z axis DRIVE POWER CABLE : RZ12-CN5-1, RZ12-CN5-2
REAR Z axis DRIVE POWER CABLE : RZ910-CN5-1, RZ910-CN
5-2
14. PC Rack Power Cable power measurement
Inspection units Inspection criteria
PC RACK POWER CABLE : L, N AC 220V±10
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-20
Note
AC/DC power activated with Ready ON.
1. MC #1 power measurement
Inspection units Inspection criteria
MC#1 power CHECK : MC1-2 , MC1-4
AC 220V±10
MC#1 power CHECK : MC1-2 , MC1-6
MC#1 power CHECK : MC1-4 , MC1-6
*Condition : Press the contact of MC#1 to access.
2. Terminal Block#1 power measurement
Inspection units Inspection criteria
TB1 AC power CHECK : 22L1 , 22L2
AC 220V±10
TB1 AC power CHECK : 22L1 , 22L3
TB1 AC power CHECK : 22L2 , 22L3
*Condition : Press the contact of MC#1 to access.
3. Relay#1,11 LED ON status check.
4. CP#,1 2 OFF
5. Disconnect the tool cable from the Safety Control Board.
6. Connect the X,Y1,Y2,WD,SW Driver CONTROL POWER Connector.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
EQUIPMENT POWER AC380V CHANGE
Page
3-19-21
Note
[EQUIPMENT POWER AC380V CHANGE]
1. Disconnect the cover and the connector from the right side of equipment.
2. In the Transformer, change the equipment power.
220V 380V
3. Assemble the cover and the connector on the right side of equipment.